Users manual Wittkop 7202
1.Important notes
1.1 Explanation of terms
1.2 General
2. Opening the electronic lock
3. Closing the electronic lock
4. Time
-
out following erroneous entries
5. Correction with the
„
C
“
button
6. Battery charge monitoring, replacing the battery
7. Emergency opening 8. Programming the electronic lock
8.1 Programming the master combination
8.1.1 Programming a new primary combination using the
emergency opening lock
8.2 Programming a user combination
8.2.1 Deleting a user combination
8.3 Programming a timed delay period
8.3.1 Opening the lock with the timed delay function activated
8.3.2 Deleting a timed delay period
8.4 Programming a time
-
lock period
8.4.1 Starting a time
-
lock period
8.5 Activating a combination interlock
8.5.1 Opening the lock with an interlock activated
8.5.2 Deleting an interlock
9. Triggering a silent alarm
10. Troubleshooting
Electronic lock
7202
Contents
•
The maximum permissible interval between any two
keypad entries is 30 seconds. If this limit is exceeded, then
the entire procedure will have to be repeated from the
beginning.
•
A signal tone sounds each time a button is pressed.
•
A 10
-
second time
-
out period will be started after invalid
combinations have been entered in three consecutive
attempts.
•
Do not damage the inspection seal on the lock as the
guarantee will otherwise be invalidated.
1. Importent notes
Please read these instructions carefully and completely before
putting the lock in operation.
•
Replace the 0 _ 1 2 3 4 5 6 factory combination
immediately by programming your own master
combination; see Section 8.1.
•
Do not use any personal data for your new master or user
combination.
Explanation of terms
User number = User number (abbreviated UNo.)
UNo. = 0 for master
UNr. = 1 to 5 users
Code = A series of digits, e.g. 4 7 6 2 3 9
Combination = A series of digits required to open the lock. It
comprises the: User number and code:
Example for the master combination
0 _ 6 5 4 7 2 1
Example of a user combination
3 _ 8 7 9 5 8 3
Factory combination = The initial combination, programmed at
the factory. The combination for this electronic lock has been
pre
-
set to
0 _ 1 2 3 4 5 6
Master combionation = Combination used by the master to open
the lock
User combination = Combinations for additional users. All user
combinations are subordinate to the master combination.
P
-
No. = Program number
LED = Light
-
emitting diode at the keypad.