Users manual Wittkop 7202

 

1.Important notes 

 

1.1 Explanation of terms 

 

1.2 General 

 

2. Opening the electronic lock 

 

3. Closing the electronic lock 

 

4. Time

-

out following erroneous entries 

 

5. Correction with the 

C

“ 

button 

 

6. Battery charge monitoring, replacing the battery 

 

7. Emergency opening 8. Programming the electronic lock 

 

8.1 Programming the master combination 

 

8.1.1 Programming a new primary combination using the 
emergency opening lock 

 

8.2 Programming a user combination 

 

8.2.1 Deleting a user combination 

 

8.3 Programming a timed delay period 

 

8.3.1 Opening the lock with the timed delay function activated 
8.3.2 Deleting a timed delay period 

 

8.4 Programming a time

-

lock period 

 

8.4.1 Starting a time

-

lock period 

 

8.5 Activating a combination interlock 

 

8.5.1 Opening the lock with an interlock activated 

 

8.5.2 Deleting an interlock 

 

9. Triggering a silent alarm 

 

10. Troubleshooting 

 

 

Electronic lock 

7202

 

 

Contents

 

 

 

• 

The maximum permissible interval between any two 

keypad entries is 30 seconds. If this limit is exceeded, then 
the entire procedure will have to be repeated from the 
beginning. 

 

• 

A signal tone sounds each time a button is pressed. 

 

• 

A 10

-

second time

-

out period will be started after invalid 

combinations have been entered in three consecutive 
attempts. 

 

• 

Do not damage the inspection seal on the lock as the 

guarantee will otherwise be invalidated. 

 

 

 

 

1. Importent notes

 

Please read these instructions carefully and completely before 
putting the lock in operation. 

 

• 

Replace the 0 _ 1 2 3 4 5 6 factory combination 
immediately by programming your own master 
combination; see Section 8.1. 

 

• 

Do not use any personal data for your new master or user 
combination. 

 

 

Explanation of terms

 

 

User number = User number (abbreviated UNo.) 

 

UNo. = 0 for master 

 

UNr. = 1 to 5 users 

 

Code = A series of digits, e.g. 4 7 6 2 3 9 

 

Combination = A series of digits required to open the lock. It 
comprises the: User number and code: 

 

Example for the master combination 

0 _ 6 5 4 7 2 1 

 

Example of a user combination 

3 _ 8 7 9 5 8 3 

 

Factory combination = The initial combination, programmed at 
the factory. The combination for this electronic lock has been 
pre

-

set to 

0 _ 1 2 3 4 5 6 

 

Master combionation = Combination used by the master to open 
the lock 

 

User combination = Combinations for additional users. All user 
combinations are subordinate to the master combination. 

 

-

 No. = Program number 

 

LED = Light

-

emitting diode at the keypad. 

 

Summary of Contents for 7202

Page 1: ... signal tone sounds each time a button is pressed A 10 second time out period will be started after invalid combinations have been entered in three consecutive attempts Do not damage the inspection seal on the lock as the guarantee will otherwise be invalidated 1 Importent notes Please read these instructions carefully and completely before putting the lock in operation Replace the 0 _ 1 2 3 4 5 6...

Page 2: ...y up to a maximum time out period of 15 minutes The time out period cannot be interrupted with the C button If you press the C button during the course of an entry sequence then all digits previously entered will be canceled Any programming mode which might have been commenced will also be terminated You must initiate programming once again from the beginning by pressing the button Exception Neith...

Page 3: ...ion must not be retained Programming is possible only with the door open and with the electronic lock released Select your new six digit combination before starting the easy programming sequence Do not use any personal data for this combination such as birthdays or other information which could be derived from knowledge about your person Store your combination in a safe place so that only you have...

Page 4: ...ls during the ti med delay period During this delay period the electronics will not respond to any keypad entries The end of this timed delay period is signaled by 15 signal tones the green LED lights The release period begins running and you can now open the elec tronic lock by entering your combination again 8 3 1 Opening the lock with the timed delay function activated If a combination interloc...

Page 5: ...ll sound 8 5 1 Opening the lock with the combination interlock feature activated duality principle When the interlock feature is active it will be necessary to enter two different combinations one after another to open the electronic lock Any two combinations may be used It is not possible for the master combination owner alone to open the lock by entering the master combination twice a second use...

Page 6: ...of force or by improper handling nor for damages to property or assets which for example are due to not closing the safe properly We recommend obtaining appropriate insurance coverage to protect the contents of your safe Your property insurance sales agent can provide details Our model 7201 to 7205 locks have been certified as Class 1 products by VdS the Property Insurers Association in Germany 10...