2. Opening the electronic lock

 

 

6. Battery monitor, replacing the battery

 

Enter either the factory combination, pressing the 0 _ 1 2 3 4 5 
6 buttons, or your own new master combination. 

 

You may press the 

C

“ 

key to correct the entry. In this case 

you will have to repeat the entire entry sequence. Correct 
entry is confirmed with a beep. The green LED will now blink 
and the electronic lock is cleared for opening for a period of 12 
seconds. The door to the safe can now be unlocked using the 
keypad lever and the fingertip grip. The green LED will blink at 
a 3

-

second interval for as long as the electronic lock is open. 

 

The keypad lever may not be under pressure before the 
acoustic and optical clearance signals are emitted. If the 
keypad lever is not used within 12 seconds to open the door, 
then the electronic lock will automatically be re

-

locked. 

 

 

1.2 General

 

 

5. Correction with the C button

 

Even though operation is very simple, you should nonetheless 
read these instructions carefully and completely before 
starting, in order to prevent operating errors. These operating 
instructions apply to an electronic lock which is installed in a 
high

-

security container such as a safe. A beep will sound briefly 

to verify the entry each time a button is pressed. No more than 
30 seconds may elapse between entries as otherwise all the 
information entered up to that point will be discarded. 

 

 

3. Closing the electronic lock

 

Close the door and turn the keypad lever back to the stop. The 
keypad lever will have to cover the red marking completely. 
The electronic lock is automatically locked in this position. Two 
signal tones of the same frequency will sound to indicate that 
the electronic lock has been locked; the green LED will light 
once. 

 

In the interest of security, attempt to turn the handle to 
ensure that the container is properly closed. 

 

 

4. Time

-

out following erroneous entries 

 

Twelve signal beeps will sound and the red LED will light if an 
invalid combination is entered. You now have three more tries 
to enter a valid combination. After the fourth consecutive 
invalid entry, however, the time

-

out period commences; the 

keypad will accept no entries during this 10

-

second period. 

This time

-

out period will be extended by 10 additional seconds 

following each subsequent invalid entry up to a maximum 
time

-

out period of 15 minutes. The time

-

out period cannot be 

interrupted with the 

C

“ 

button. 

 

If you press the 

C

“ 

button during the course of an entry sequence, 

then all digits previously entered will be canceled. Any 
programming mode which might have been commenced will also 
be terminated. You must initiate programming once again, from 
the beginning, by pressing the 

„*“ 

button. 

 

Exception: Neither the time

-

out period following erroneous entries 

nor the low battery warning period can be interrupted with the 

C

“ 

button. 

 

If the battery charge is insufficient, then a high

-

low warning beep 

will sound 10 times after the combination is entered and the red 
and green LEDs will blink alternately. This is to remind you to 
install two new 1.5 volt (AA alkaline) batteries within the next few 
days. 

 

Replacing the batteries

: The battery compartment cover is located 

to the right of the keypad housing. Slide the battery compartment 
cover off the keypad housing, in the direction indicated by the 
arrow 

 

Remove the old batteries and replace them with two new 1.5 volt 
AA (alkaline) batteries. The direction in which the batteries are to 
be installed is shown inside the battery compartment cover. The 
programmed combination will be retained during battery 
replacement. 

 Do not use rechargable batteries.

 

 

7. Emergency opening

 

The electronic lock is also equipped with an emergency release 
feature (double

-

bit safety lock). This special function makes it 

possible to open the container even though the batteries were not 
changed in due time or if the electronics failed or the combination 
was lost. Furthermore, using the emergency key to unlock and open 
the door prepares the system for programming a new combination; 
see 8.2. The access to the emergency release lock is inside the 
battery compartment; behind the batteries; see Figure 1. 

 

Store the emergency release key carefully in a secure place. Do not 
leave it in the safe! 

 

Functioning: Insert the supplied double

-

bit key in the emergency 

release lock. (The mark on the head of the key must point away from 
the hinge.) Now turn the key clockwise, all the way to the stop; use 
the keypad lever to release the electronic lock and open the door. 
Close the door to the safe. Move the keypad lever downward (red 
screw cover cap must be concealed by the keypad lever). Turn the 
key counterclockwise and withdraw it from the emergency release 
lock. Slide the battery compartment cover back on to the keypad 
housing and affix it with the cross head screw. 

 

Summary of Contents for 7202

Page 1: ... signal tone sounds each time a button is pressed A 10 second time out period will be started after invalid combinations have been entered in three consecutive attempts Do not damage the inspection seal on the lock as the guarantee will otherwise be invalidated 1 Importent notes Please read these instructions carefully and completely before putting the lock in operation Replace the 0 _ 1 2 3 4 5 6...

Page 2: ...y up to a maximum time out period of 15 minutes The time out period cannot be interrupted with the C button If you press the C button during the course of an entry sequence then all digits previously entered will be canceled Any programming mode which might have been commenced will also be terminated You must initiate programming once again from the beginning by pressing the button Exception Neith...

Page 3: ...ion must not be retained Programming is possible only with the door open and with the electronic lock released Select your new six digit combination before starting the easy programming sequence Do not use any personal data for this combination such as birthdays or other information which could be derived from knowledge about your person Store your combination in a safe place so that only you have...

Page 4: ...ls during the ti med delay period During this delay period the electronics will not respond to any keypad entries The end of this timed delay period is signaled by 15 signal tones the green LED lights The release period begins running and you can now open the elec tronic lock by entering your combination again 8 3 1 Opening the lock with the timed delay function activated If a combination interloc...

Page 5: ...ll sound 8 5 1 Opening the lock with the combination interlock feature activated duality principle When the interlock feature is active it will be necessary to enter two different combinations one after another to open the electronic lock Any two combinations may be used It is not possible for the master combination owner alone to open the lock by entering the master combination twice a second use...

Page 6: ...of force or by improper handling nor for damages to property or assets which for example are due to not closing the safe properly We recommend obtaining appropriate insurance coverage to protect the contents of your safe Your property insurance sales agent can provide details Our model 7201 to 7205 locks have been certified as Class 1 products by VdS the Property Insurers Association in Germany 10...

Reviews: