[4] Configure IP
4-10 Configuring the Module in a DEChub 900
[2] Set In-Band Interface IP Address
This option prompts you to change or enter the module’s in-band IP address, subnet
mask, and default gateway for the in-band interface. If an IP address was previously
configured, the screen displays an in-band IP address.
NOTE
If you would like to change a previously configured IP address on the module, you
must first change the IP address and then, reboot the module in order for the new
IP address to take effect.
You do not need to configure the module with a subnet mask for SNMP
communications with management stations located on the same subnet as the module.
The factory default setting is no in-band address.
The following example shows the dialog associated with this option:
Enter selection : 2
DECserver 900MC
=================================================================
IN-BAND INTERFACE IP ADDRESS CONFIGURATION
example: 16.20.40.156
To delete the IP address, enter 0 in the appropriate
Interface IP Address Subnet Mask Def.Gateway Other Info
In-Band
OBM Port Active
==================================================================
Enter the IP address [] : 16.20.216.91 <Return>
Enter the Subnet Mask [] : 255.255.255 0 : <Return>
Enter the Default Gateway [] 16.21.0.1 <Return>
.
Press Return for IP Configuration Menu.....
Format: The standard 4 octet dotted decimal notation in which
each octet of the address is represented as a decimal
separated by a ’.’ character.
address field.
- slot 3