AT Commands F-79
Register Descriptions
:T10=
n Primary XOFF Flow Control Character
Range:
Where n is a decimal from 0 to 255, representing an 8-bit character.
Default:
13 hexadecimal (or 19 decimal) <DC3>
Defines the character used for primary XOFF flow control on the modem and serial
ports. Enable primary flow control with \Q1, \Q4, \G1, or \G2.
NOTE
With modem port flow control, both modems must have the same primary flow
control characters set during normal connections.
:T11=
n Secondary XON Flow Control Character
Range:
Where n is a decimal from 0 to 255, representing an 8-bit character.
Default:
F9 hexadecimal (or 249 decimal)
Defines the character used for secondary XON flow control on the modem’s serial port.
For secondary flow control to take effect, you must set either -F1\Q1 or -F1\Q4.
:T12=
n Secondary XOFF Flow Control Character
Range:
Where n is a decimal from 0 to 255, representing an 8-bit character.
Default:
FB hexadecimal (or 251 decimal)
Defines the character used for secondary XOFF flow control on the modem serial port.
For secondary flow control to take effect, you must set either -F1\Q1 or -F1\Q4.
:T13=
n Automode Timer
Range:
Where n is an integer from 0 to 255, representing tenths of a second.
Default:
15 (1.5 seconds)
Sets a timer to allow modems to connect in Automode. If the originating modem is set
to 2400 bps or lower and has a problem connecting to your modem, we recommend
increasing the value of this command to 40 (4 seconds) on the answering modem.
NOTE
Use :T13 only when %L3 is in effect.