
About Your System
55
SATA port
x
device auto-
sensing error
SATA port
x
device
configuration
error.
SATA port
x
device error
The drive connected to the
specified SATA port is faulty.
Replace the faulty drive.
Sector not found
Seek error
Seek operation
failed
Faulty hard drive, USB
device, or USB medium.
Replace the USB medium or
device. Ensure that the USB
or SAS backplane cables are
properly connected. See
"Troubleshooting a USB
Device" on page 174 or
"Troubleshooting a Hard
Drive" on page 186 for the
appropriate drive(s) installed
in your system.
Shutdown failure
General system error.
See "Getting Help" on
page 203.
The amount of
system memory has
changed.
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module. See
"Troubleshooting System
Memory" on page 181.
Time-of-day
clock stopped.
Faulty battery or faulty chip. See "Troubleshooting the
System Battery" on page 178.
Message
Causes
Corrective Actions
book.book Page 55 Wednesday, January 20, 2010 10:20 AM
Summary of Contents for PowerEdge R910
Page 62: ...62 About Your System ...
Page 84: ...84 Using the System Setup Program and UEFI Boot Manager ...
Page 172: ...172 Installing System Components ...
Page 192: ...192 Troubleshooting Your System ...
Page 204: ...204 Getting Help ...
Page 210: ...Index 210 ...