38
About Your System
E2021
Incorrect
memory
configur-
ation. Review
User Guide.
Incorrect memory
configuration.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 181.
E2022
General
failure
during POST.
Check screen
message.
General failure after video.
Check screen for specific
error messages.
E2025
QPI
initializati
on error.
Contact
support.
QuickPath Interconnect
(QPI) failure.
See "Getting Help" on
page 203.
E2026
Memory
initializati
on error.
Contact
support.
Invalid memory
configuration.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines"
on page 92. See "Getting
Help" on page 203.
E2110
Multibit
Error on DIMM
##. Reseat
DIMM.
The memory module in slot
"##" has had a multi-bit
error (MBE).
See "Troubleshooting
System Memory" on
page 181.
E2111
SBE log
disabled on
DIMM ##.
Reseat DIMM.
The system BIOS has
disabled memory single-bit
error (SBE) logging and will
not log any more SBEs until
the system is rebooted. "##"
represents the memory
module implicated by the
BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 181.
Code
Text
Causes
Corrective Actions
book.book Page 38 Wednesday, January 20, 2010 10:20 AM
Summary of Contents for PowerEdge R910
Page 62: ...62 About Your System ...
Page 84: ...84 Using the System Setup Program and UEFI Boot Manager ...
Page 172: ...172 Installing System Components ...
Page 192: ...192 Troubleshooting Your System ...
Page 204: ...204 Getting Help ...
Page 210: ...Index 210 ...