About Your System
31
E1631
System power
draw exceeded
threshold.
Contact
support.
The processors and memory
throttling is not sufficient to
keep system power
consumption below the
maximum safe level with
current power supply
configuration.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E1632
PowerSafe
event.
Contact
support.
The processors and memory
have been throttled to keep
system power consumption
below the maximum safe
level with current power
supply configuration.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E1710
I/O channel
check error.
Review &
clear SEL.
The system BIOS reported
an I/O channel check.
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 203.
E1711
PCI parity
error on Bus
## Device ##
Function ##.
The system BIOS reported a
PCI parity error on a
component that resides in
PCI configuration space at
bus ##, device ##,
function ##.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 189.
PCI parity
error on Slot
#. Review &
clear SEL.
The system BIOS reported a
PCI parity error on a
component that resides in
the specified slot.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 189.
Code
Text
Causes
Corrective Actions
book.book Page 31 Wednesday, January 20, 2010 10:20 AM
Summary of Contents for PowerEdge R910
Page 62: ...62 About Your System ...
Page 84: ...84 Using the System Setup Program and UEFI Boot Manager ...
Page 172: ...172 Installing System Components ...
Page 192: ...192 Troubleshooting Your System ...
Page 204: ...204 Getting Help ...
Page 210: ...Index 210 ...