About Your System
E2014
CMOS RAM
failure.
Power cycle
AC.
CMOS failure. CMOS RAM
not functioning properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E2015
DMA
Controller
failure.
Power cycle
AC.
DMA controller failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E2016
Interrupt
Controller
failure.
Power cycle
AC.
Interrupt controller failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E2017
Timer refresh
failure.
Power cycle
AC.
Timer refresh failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E2018
Programmable
Timer error.
Power cycle
AC.
Programmable interval
timer error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E2019
Parity error.
Power cycle
AC.
Parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
Code
Text
Causes
Corrective Actions
book.book Page 36 Wednesday, January 20, 2010 10:20 AM
Summary of Contents for PowerEdge R910
Page 62: ...62 About Your System ...
Page 84: ...84 Using the System Setup Program and UEFI Boot Manager ...
Page 172: ...172 Installing System Components ...
Page 192: ...192 Troubleshooting Your System ...
Page 204: ...204 Getting Help ...
Page 210: ...Index 210 ...