34
About Your System
E1812
Hard drive ##
removed.
Check drive.
The specified hard drive has
been removed from the
system.
Information only.
E1813
Internal Dual
SD Module
Card #
failed. Check
SD card.
The internal dual SD
module card has failed.
Reseat the internal dual
SD module card.
If the problem persists,
see "Getting Help" on
page 203.
E1814
Internal SD
Module Card #
write-
protected.
Check SD
card.
The internal dual SD
module card is write-
protected and cannot be
used.
Change the write-protect
switch setting on SD card.
E1815
Internal Dual
SD Module
redundancy
lost. Check
SD cards.
The internal dual SD
module bootable media is
no longer redundant.
Initiate a rebuild on the
next POST execution.
Reseat the internal dual
SD module card. See
"Removing an Internal SD
Card" on page 142 and
"Installing an Internal SD
Card" on page 142.
If the problem persists,
see "Getting Help" on
page 203.
E1A14
SAS cable A
failure.
Check
connection.
SAS cable A is missing or
bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 203.
Code
Text
Causes
Corrective Actions
book.book Page 34 Wednesday, January 20, 2010 10:20 AM
Summary of Contents for PowerEdge R910
Page 62: ...62 About Your System ...
Page 84: ...84 Using the System Setup Program and UEFI Boot Manager ...
Page 172: ...172 Installing System Components ...
Page 192: ...192 Troubleshooting Your System ...
Page 204: ...204 Getting Help ...
Page 210: ...Index 210 ...