40
About Your System
W1101
CPU VCACHE
Regulator
temp
exceeding
range. Check
fans.
The regulator temperature
has reached a point outside
of the allowed range.
See "Troubleshooting
System Cooling
Problems" on page 180. If
the problem persists, see
"Getting Help" on
page 203.
W1102
Mem Voltage
Regulator
temp
exceeding
range. Check
fans
The regulator temperature
has reached a point outside
of the allowed range.
See "Troubleshooting
System Cooling
Problems" on page 180. If
the problem persists, see
"Getting Help" on
page 203.
W1228
RAID
Controller
battery
capacity <
24hr.
Warns predictively that the
RAID battery has less than
24 hours of charge left.
Allow RAID battery to
charge to greater than 24
hours of sustained charge.
If problem persists,
replace the RAID battery.
See "Installing the RAID
Battery" on page 147.
W1627
Power
required >
PSU wattage.
Check PSU and
config.
The system configuration
requires more power than
what the power supply can
provide.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
W1628
Performance
degraded.
Check PSU and
system
configur-
ation.
The system configuration
requires more power than
what the power supply can
provide, but it can boot if
throttled.
Turn off power to the
system, reduce the
hardware configuration or
install higher-wattage
power supplies, and then
restart the system.
Code
Text
Causes
Corrective Actions
book.book Page 40 Wednesday, January 20, 2010 10:20 AM
Summary of Contents for PowerEdge R910
Page 62: ...62 About Your System ...
Page 84: ...84 Using the System Setup Program and UEFI Boot Manager ...
Page 172: ...172 Installing System Components ...
Page 192: ...192 Troubleshooting Your System ...
Page 204: ...204 Getting Help ...
Page 210: ...Index 210 ...