About Your System
29
E141F
CPU #
protocol
error. Power
cycle AC.
The system BIOS reported a
processor protocol error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E1420
CPU Bus
parity error.
Power cycle
AC.
The system BIOS reported a
processor bus parity error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E1421
CPU #
initializati
on error.
Power cycle
AC.
The system BIOS reported a
processor initialization error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E1422
CPU # machine
check error.
Power cycle
AC.
The system BIOS reported a
machine check error.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E1610
Power Supply
# (### W)
missing.
Check power
supply.
Specified power supply was
removed or is missing from
the system.
See "Troubleshooting
Power Supplies" on
page 179.
E1614
Power Supply
# (### W)
error. Check
power supply.
Specified power supply
failed.
See "Troubleshooting
Power Supplies" on
page 179.
Code
Text
Causes
Corrective Actions
book.book Page 29 Wednesday, January 20, 2010 10:20 AM
Summary of Contents for PowerEdge R910
Page 62: ...62 About Your System ...
Page 84: ...84 Using the System Setup Program and UEFI Boot Manager ...
Page 172: ...172 Installing System Components ...
Page 192: ...192 Troubleshooting Your System ...
Page 204: ...204 Getting Help ...
Page 210: ...Index 210 ...