Figure 38. Server Module Partitions
1.
metal partition
2.
outer chassis wall
3.
server module partition between Slots 1 and 3
4.
server module partition between Slots 2 and 4
5.
inner chassis wall
Removing The Server Module Partitions
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
NOTE: You must remove the server module partitions to install full-height server modules.
1.
If installed, remove the front bezel.
2.
Turn off the server modules using the operating system commands or the CMC.
3.
Turn off the enclosure, including any attached peripherals, and disconnect the enclosure from the electrical outlet.
4.
Remove the server modules or server module blanks.