0-20 Display Line 1.1 Small
Option:
Function:
[1675]
Analog In X30/11
Actual value at input X30/11
either as reference or protection
value.
[1676]
Analog In X30/12
Actual value at input X30/12
either as reference or protection
value.
[1677]
Analog Out X30/8
[mA]
Actual value at output X30/8 in
mA. Use
6-60 Terminal X30/8
Output
to select the value to be
shown.
[1678]
Analog Out X45/1
[mA]
[1679]
Analog Out X45/3
[mA]
[1680]
Fieldbus CTW 1
Control word (CTW) received
from the bus master.
[1682]
Fieldbus REF 1
Main reference value sent with
control word from the bus
master.
[1684]
Comm. Option STW
Extended serial communication
option status word.
[1685]
FC Port CTW 1
Control word (CTW) received
from the bus master.
[1686]
FC Port REF 1
Status word (STW) sent to the
bus master.
[1690]
Alarm Word
One or more alarms in a Hex
code.
[1691]
Alarm Word 2
One or more alarms in a Hex
code.
[1692]
Warning Word
One or more warnings in a Hex
code.
[1693]
Warning Word 2
One or more warnings in a Hex
code.
[1694]
Ext. Status Word
One or more status conditions in
a Hex code.
[1836]
Analog Input X48/2
[mA]
[1837]
Temp. Input X48/4
[1838]
Temp. Input X48/7
[1839]
Temp. Input X48/10
[1860]
Digital Input 2
[1890]
Process PID Error
[1891]
Process PID Output
[1892]
Process PID Clamped
Output
[1893]
Process PID Gain
Scaled Output
0-20 Display Line 1.1 Small
Option:
Function:
[3019]
Wobble Delta Freq.
Scaled
[3110]
Bypass Status Word
[3111]
Bypass Running
Hours
[3401]
PCD 1 Write to MCO
[3402]
PCD 2 Write to MCO
[3403]
PCD 3 Write to MCO
[3404]
PCD 4 Write to MCO
[3405]
PCD 5 Write to MCO
[3406]
PCD 6 Write to MCO
[3407]
PCD 7 Write to MCO
[3408]
PCD 8 Write to MCO
[3409]
PCD 9 Write to MCO
[3410]
PCD 10 Write to MCO
[3421]
PCD 1 Read from
MCO
[3422]
PCD 2 Read from
MCO
[3423]
PCD 3 Read from
MCO
[3424]
PCD 4 Read from
MCO
[3425]
PCD 5 Read from
MCO
[3426]
PCD 6 Read from
MCO
[3427]
PCD 7 Read from
MCO
[3428]
PCD 8 Read from
MCO
[3429]
PCD 9 Read from
MCO
[3430]
PCD 10 Read from
MCO
[3440]
Digital Inputs
[3441]
Digital Outputs
[3450]
Actual Position
[3451]
Commanded Position
[3452]
Actual Master
Position
[3453]
Slave Index Position
[3454]
Master Index Position
[3455]
Curve Position
[3456]
Track Error
[3457]
Synchronizing Error
[3458]
Actual Velocity
[3459]
Actual Master
Velocity
[3460]
Synchronizing Status
Parameter Descriptions
FC 300 Programming Guide
MG33MD22 - VLT
®
is a registered Danfoss trademark
3-7