Par.
No.
#
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion
index
Type
33-54 Terminal X57/5 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-55 Terminal X57/6 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-56 Terminal X57/7 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-57 Terminal X57/8 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-58 Terminal X57/9 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-59 Terminal X57/10 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-60 Terminal X59/1 and X59/2 Mode
[1] Output
2 set-ups
FALSE
-
Uint8
33-61 Terminal X59/1 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-62 Terminal X59/2 Digital Input
[0] No function
2 set-ups
TRUE
-
Uint8
33-63 Terminal X59/1 Digital Output
[0] No function
2 set-ups
TRUE
-
Uint8
33-64 Terminal X59/2 Digital Output
[0] No function
2 set-ups
TRUE
-
Uint8
33-65 Terminal X59/3 Digital Output
[0] No function
2 set-ups
TRUE
-
Uint8
33-66 Terminal X59/4 Digital Output
[0] No function
2 set-ups
TRUE
-
Uint8
33-67 Terminal X59/5 Digital Output
[0] No function
2 set-ups
TRUE
-
Uint8
33-68 Terminal X59/6 Digital Output
[0] No function
2 set-ups
TRUE
-
Uint8
33-69 Terminal X59/7 Digital Output
[0] No function
2 set-ups
TRUE
-
Uint8
33-70 Terminal X59/8 Digital Output
[0] No function
2 set-ups
TRUE
-
Uint8
33-8* Global Parameters
33-80 Activated Program Number
-1 N/A
2 set-ups
TRUE
0
Int8
33-81 Power-up State
[1] Motor ON
2 set-ups
TRUE
-
Uint8
33-82 Drive Status Monitoring
[1] On
2 set-ups
TRUE
-
Uint8
33-83 Behavior After Error
[0] Coast
2 set-ups
TRUE
-
Uint8
33-84 Behavior afterEsc.
[0] Controlled stop
2 set-ups
TRUE
-
Uint8
33-85 MCO Supplied by External 24VDC
[0] No
2 set-ups
TRUE
-
Uint8
33-86 Terminal at alarm
[0] Relay 1
2 set-ups
TRUE
-
Uint8
33-87 Terminal state at alarm
[0] Do nothing
2 set-ups
TRUE
-
Uint8
33-88 Status word at alarm
0 N/A
2 set-ups
TRUE
0
Uint16
33-9* MCO Port Settings
33-90 X62 MCO CAN node ID
127 N/A
2 set-ups
TRUE
0
Uint8
33-91 X62 MCO CAN baud rate
[20] 125 Kbps
2 set-ups
TRUE
-
Uint8
33-94 X60 MCO RS485 serial termination
[0] Off
2 set-ups
TRUE
-
Uint8
33-95 X60 MCO RS485 serial baud rate
[2] 9600 Baud
2 set-ups
TRUE
-
Uint8
Parameter Lists
FC 300 Programming Guide
4-34