Appendix 1 Parameter List
188
Owner’s Manual of BECS- 185 Computerized Control System
No.
Name of Parameter Default Value
Range of Value
Remarks
Display
C79
Automatic Jump
No
No, Yes
The same to above
C80
Auto Jump Stitch
Len
8.0mm
6.0mm~12.0mm
The same to above
Thread-breakage Detection Parameters
B05
T. B. Detect
Yes
No, Yes
B11
Sti. Not T.B. Detect
8 stitch
0 stitch ~15 stitch
B06
Stop machine after
T.B. detect
Yes
No, Yes
B12
T. B. Detect When
Jump
No
No, Yes
C27
Detect T. B. Mode
Coupler
Coupler, T.B.D Board
C67
Sensitivity of Upper
Thread
6
1
~
15
C68
Sensitivity of Under
Thread
6
1
~
15
C69
Filter Sti. For Upper
Thread
6 Sti
1~6 Sti.
C70
Filter Sti. For Under
Thread
6 Sti
1~6 Sti.
C90
T.B.D Device Type
Spring
Spring, Wheel,
Wheel
Frame Parameter
C06
Frame Curve &
Angle
F6/230
F1/230,240,250,260,2
70
F2/230,240,250,260,2
70
F3/230,240,250,260,2
70,
280,290
F4/230,240,250,260,2
70,
280,290
F5/230,240,250,260,2
70,
280,290
F6/230,240,250,260,2
70
F2 and F4 are frame curve.
The later values are the angles
of frame acting.
Summary of Contents for BECS-185