Chapter 5 Setting of Embroidery Parameters
64
Owner’s Manual of BECS- 185 Computerized Control System
5.2.2.
Memory of Manual Color-changing
In embroidery confirmation status, the user can choose whether to store the manual
color-changing’s needle position into the color-changing order unit. Its purposes are as
follows: 1) if mistakes are found for the automatic color-changing order in embroidery, the
color-changing order can be modified with manual color-changing operation. 2) When a new
design is embroidered with manual color-changing once, the color-changing order will be set
for the design.
To use this function, the user should set the parameter “Store Manual Color” as “Yes”.
Note: the parameter value will automatically change into “No” at each end of embroidery.
5.2.3.
Brake Adjustment (A Must for New Machine)
This function is to adjust the control parameters for braking, so as to fit machines with
different mechanical characters, which is also able to change with the machine running. Thus
this function can help the machinery parts to work better with the computer. The function
depends on the parameters “Set Brake Para”.
“Set Brake Para” is to adjust the stop position of the main shaft. When the main shaft
often stops at the position below 100 degree, the user can increase the parameter value. When
the main shaft often stops at the position over 100 degree, the user can decrease the parameter
value. Thus the user can adjust the value to let the main shaft stop close to 100 degree. The
value can be set between 0 and 30.
After adjusting this parameter, the user can click the task swift key on the panel to return
to the main interface. Click
and
, to check the effects of the parameter
adjustment. If the user is not satisfied with the effects, he can press the swift key on the panel
to return to the parameter setting interface, where he can adjust the parameter setting again.
Close the parameter setting interface in the end.
5.2.4.
Forbid Design Output
The function is to forbid copying the designs in memory (into the disk). If the machine
administrator set “No Output Design” as “Yes”, other persons are unable to output the designs
to the disk. If the user needs to output, he has to cancel “No Output Design” first.
For using this function, user can set the administrator password in the system at first
(Refer to 10.7). you can change this parameter after decoding the password of administrator.