DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
86
Format
show flow_meter {[profile_id <value 1-512> | profile_name <name 32>] {access_id <value 1- 128>}}
Parameters
profile_id
- (Optional) Specifies the profile ID.
<value 1-512>
- Enter the profile ID used here. This value must be between 1 and 512.
profile_name
- (Optional) Specifies the name of the profile.
<name 32>
- Enter the profile name used here. The maximum length is 32 characters.
access_id
- (Optional) Specifies the access ID.
<value 1-
128>
- Enter the access ID used here. This value must be between 1 and 128.
Restrictions
None.
Example
To display the flow metering configuration:
DGS-1510-28XMP/ME:admin# show flow_meter
Command: show flow_meter
Flow Meter Information
------------------------------------------------------------------------------
Profile ID:1 Access ID:1 Mode : trTCM / ColorBlind
CIR(Kbps):1000 CBS(Kbyte):2000 PIR(Kbps):2000 PBS(Kbyte):2000
Action:
Conform : Permit Counter: Enabled
Exceed : Permit Replace DSCP: 60 Counter: Enabled
Violate : Drop Counter: Disabled
------------------------------------------------------------------------------
Total Entries: 1
DGS-1510-28XMP/ME:admin#
6-7
config time_range
Description
This command is used to define a specific range of time to activate a function on the Switch by specifying which
time range in a day and which days in a week are covered in the time range. Note that the specified time range is
based on the SNTP time or the configured time. If this time is not available, the time range will not be met.
Format
config time_range <range_name 32> [hours start_time <time hh:mm:ss> end_time <time hh:mm:ss>
weekdays <daylist> | delete]
Parameters
<range_name 32>
- Enter the time range name used here. This name can be up to 32 characters long.
Summary of Contents for DGS-1510/ME Series
Page 1: ......