DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
33
Example
To display PVID auto-assignment state:
DGS-1510-28XMP/ME:admin# show pvid auto_assign
Command: show pvid auto_assign
PVID Auto-assignment: Enabled
DGS-1510-28XMP/ME:admin#
3-15
config gvrp
Description
This command is used to configure the GVRP timer’s value. The default value for Join time is 200 milliseconds; for
Leave time is 600 milliseconds; for Leave All time is 10000 milliseconds.
Format
config gvrp [timer {join < value 100-100000> | leave < value 100-100000> | leaveall <value 100-100000>} |
nni_bpdu_addr [dot1d | dot1ad]]
Parameters
timer
- Specifies that the GVRP timer parameter will be configured.
join
- (Optional) Specifies the Join time will be set.
<value 100-100000>
- Enter the time used here. This value must be between 100 and 100000.
leave
- (Optional) Specifies the Leave time will be set.
<value 100-100000>
- Enter the time used here. This value must be between 100 and 100000.
leaveall
- (Optional) Specifies the Leave All time will be set.
<value 100-100000>
- Enter the time used here. This value must be between 100 and 100000.
nni_bpdu_addr
- Specifies to determine the BPDU protocol address for GVRP in service provide site. It can use
802.1d GVRP address, 802.1ad service provider GVRP address or a user defined multicast address. The
range of the user defined address is 0180C2000000 - 0180C2FFFFFF.
dot1d
- Specifies that the NNI BPDU protocol address value will be set to Dot1d.
dot1ad
- Specifies that the NNI BPDU protocol address value will be set to Dot1ad.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To set the Join time to 200 milliseconds:
Summary of Contents for DGS-1510/ME Series