DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
453
Parameters
None.
Restrictions
None.
Example
To display the device environment:
DGS-1510-28XMP/ME:admin#show environment
Command: show environment
Temperature Trap State : Enabled
Temperature Log State : Enabled
Internal Power : (Not Support)
External Power : None
Current Temperature(Celsius) : 28
High Warning Temperature Threshold(Celsius) : 79
Low Warning Temperature Threshold(Celsius) : 11
DGS-1510-28XMP/ME:admin#
53-3
config temperature threshold
Description
This command is used to configure the warning threshold for high and low temperature.
Format
config temperature threshold {high <temperature -500-500> | low <temperature -500-500>}(1)
Parameters
high
- Specifies the high threshold value. The high threshold must bigger than the low threshold.
<temperature -500-500>
- Enter the high threshold temperature.
low
- Specifies the low threshold value.
<temperature -500-500>
- Enter the low threshold temperature.
Restrictions
Only Administrators and Operators can issue this command.
Example
To configure the warning temperature threshold: