DGS-1510/ME Series Metro Ethernet Switch CLI Reference Guide
55
5-6
create authen_login
Description
This command is used to create a user-defined method list of authentication methods for user login. The maximum
supported number of the login method lists is 8.
Format
create authen_login method_list_name <string 15>
Parameters
<string 15>
- Enter the user-defined method list name. This value can be up to 15 characters long.
Restrictions
Only Administrators can issue this command.
Example
To create a user-defined method list for user login:
DGS-1510-28XMP/ME:admin# create authen_login method_list_name login_list_1
Command: create authen_login method_list_name login_list_1
Success.
DGS-1510-28XMP/ME:admin#
5-7
config authen_login
Description
This command is used to configure a user-defined or default method list of authentication methods for user login.
The sequence of methods will effect the altercation result. For example, if the sequence is first, then
TACACS and local, when the user tries to login, the authentication request will be sent to the first server host in
built-in server group. If the first server host in group is missing, the authentication request will
be sent to the second server host in group, and so on. If all server hosts in group are missing,
the authentication request will be sent to the first server host in TACACS group and so on. If all server hosts in
TACACS group are missing, the local account database in the device is used to authenticate this user. When the
user logs in the device successfully while using methods like TACACS/XTACACS//RADIUS built-in or
user-defined server groups or none, the “user” privilege level is assigned only. If the user wants to get admin
privilege level, user must use the
enable admin
command to promote his privilege level. But when local method is
used, the privilege level will depend on this account privilege level stored in the local device.
Format
config authen_login [default | method_list_name <string 15>] method {tacacs | xtacacs | | radius |
server_group <string 15> | local | none}
Parameters
default
- Specifies the default method list of authentication methods.
Summary of Contents for DGS-1510/ME Series
Page 1: ......