DES-1228/ME Layer 2 Metro Ethernet Switch CLI Reference Manual
272
Example usage
To configure PPPoE circuit ID insertion:
DES-1228/ME:4#config pppoe circuit_id_insertion ports 1-24 state enable circuit_
id ip
Command: config pppoe circuit_id_insertion ports 1-24 state enable circuit_id ip
Success.