93
CTC EcoZenith i360
SmartGrid Low price °C
10 (Off, 1...30)
Setting to increase temperature at energy price "Low
price", via SmartGrid.
Both SmartGrid A and SmartGrid B must be defined in
the remote control menu for this menu to be displayed.
Read more in the "Def. Remote Control /SmartGrid A/B"
section of the "Installer/Define" chapter.
SmartGrid Overcapacity °C
10 (Off, 1...30)
Setting to increase temperature at energy price
"Overcapacity", via SmartGrid.
Both SmartGrid A and SmartGrid B must be defined
with a remote control input for this menu to be
displayed.
Read more in the "Def. Remote Control /SmartGrid A/B"
section of the "Installer/Define" chapter.
Min rps DHW charging
50 (50...100)
Lowest compressor speed during hot water charging.
When the heat pump switches from heating to hot
water, this RPS is used for hot water.
Run time DHW circ. (min)
4 (1 to 90)
The length of time that DHW circulation should active
during each period. Displayed if "DHW circulation" has
been defined in the "Installer/Define/DHW" menu.
Time DHW circ. (min)
15 (5...90)
Time between periods of DHW circulation. Displayed
if "DHW circulation" has been defined in the "Installer/
Define/DHW" menu.
DHW circ. schedule
This menu displays the scheduled weekday periods
when the DHW circulation pump is to run. The menu bar
is displayed if:
• "DHW circulation" has been defined in the
"Installer/Define/DHW" menu.
• a "Weekly Program" is defined for the DHW
Circulation" function in the "Installer/Define/
Remote Control" menu.
For more information, refer to:
• chapter "Weekly Program" for schedule setting.
• section "Def. Remote Control" in the
"Installer / Define" chapter for defining the remote
control function.