CTC EcoZenith i360
14. Factory settings
Designation
Factory
setting
Min value Max value
Alternative
Set during
Installation
Heating circuit
Max primary flow °C
60
30
70
Min primary flow °C
Off
15
65
Off
Heating, mode
Auto
Auto On
Off
Heating mode, ext
-
Auto On
Off
Heat off, outside °C
18
2
30
Heating off, time
120
30
240
Inclination °C
50
25
85
Adjustment °C
0
-20
20
Night reduction off °C
5
-40
40
Room temp reduced °C
-2
-40
0
Primary flow reduced °C
-3
-40
0
Alarm, low room temp °C
5
-40
40
Smart low price. °C
1
0
5
Off
Smart over capacity °C
2
0
5
Off
Max time heating
20
10
120
Charge pump %
60
25
100
Drying period mode
Off
1
3
Off
Drying period temp °C
25
25
55
Heat pump
Compressor
Blocked
Permitted
Brine pump on (CTC EcoPart)
Auto
10d
On
Stop at outdoor temp °C (EcoAir)
-22
-22
10
Tariff HP
-
Off
On
Smart blocking HP
-
Off
On
Start at degree minute
-60
-900
-30
HS<->DHW time (sec)
120
30
240
Max rps
100
50
120 (80)
Max rps warm temp
50
50
100
Ext. silent mode rps
50
20
100
Cold temp limit
0
-15
0
Warm temp limit
20
0
20
Electric heater
Max el. heater kW
9.1*
0
11.9/9/10*
Max el. heater DHW kW
9.1*
0
11.9/9/10*
Start at degree minute
-500
-900
-30
Diff step, degree minute
-50
-300
-20
Main fuse A
20
10
90
Conv. factor curr. sensors
1
1
10
Tariff el.
-
No
Yes
Smart block immersion
-
No
Yes
*Applies to 3x400V, for other variants see Electrical data - Technical data.
For language choices "German" and "French" the max electric power is factory set at 0.0 kW.