78
CTC EcoZenith i360
12.8.5
Stored Operation data
This menu shows cumulative operation values.
The operation values shown in the menu screenshots
are only examples. The historical operational info
presented varies depending on the language choice.
Total operation time h
3500
Shows the total time the product has been powered.
Max primary flow °C
51
Shows the highest temperature that has been supplied
to the heating circuit.
El. heat (kWh)
250
Shows how much additional heat has been used.
Compressor:
Energy output (kWh)
10000
Estimated energy emitted from the heat pump.
The value is presented only for language choices
"Norwegian" and "German".
(The value is not calculated for models CTC GSi 600,
CTC EcoPart 600, CTC EcoAir 600, these are given the
value 0).
Operation time /24 h:m
07:26
Shows total operating time during the last 24 hours.
Starts /24 h
15
Shows the number of starts in the last 24 hours.
Total operation time
1800
Displays total compressor operating time in hours.