83
CTC EcoZenith i360
12.10 Settings
i
First define the desired functions,
see "Installer/Define". Settings are
only displayed for enabled functions.
Menu: "Installer/Settings".
Settings can be made here for, among other things, the
house’s heating and cooling needs. It is important that
the basic heating setting is right for your home. Values
which are set incorrectly may mean that your property is
not warm enough or that an unnecessarily large amount
of energy is being used to heat your property.
12.10.1
Settings Heating circuit 1-2
Max primary flow °C
55 (30...80)
Maximum permitted temperature supplied to the
respective heating circuit.
Min primary flow °C
Off (Off/15...65)
Minimum permitted temperature supplied to the
respective heating circuit.
Heating, mode
Auto (Auto/On/Off)
Switching between heating season and summer mode
can take place automatically (Auto) or a selection can be
made here to set the heating to "On" or "Off".
•
Auto
= switching the heating season On and Off
carried out automatically.
•
On
= Continuous heating season, the radiator
pump circulates constantly.
•
Off
= there is no heating, the radiator pump does
not run (is turned over).
Heating mode, ext.
Auto (Auto/On/Off)
The heat mode selected in this menu can be enabled/
disabled externally.
This menu bar is displayed for the current heating circuit
if a remote control input or a weekly schedule has been
defined for the function.
Read more in the "Def. Remote Control" section of the
"Installer / Define" chapter.
Part of the "Installer /Settings/Heating Circuit" menu.
Part of the "Installer/Settings/Heating Circuit/Heating Circuit 1"
menu.