background image

User's Information

Document 1192

User's Information
Manual for

Endurance

EBP Series Modulating Combination Boiler

(natural or propane gas)

EDP Series Modulating Hydronic Boiler

(natural or propane gas)

EDN Series Non-ferrous

Modulating Hydronic Boiler
(natural or propane gas)

H2314700-

WARNING

If the information in this manual is not
followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.

Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

nearby phone. Follow the gas supplier's
instructions.

• If you cannot reach your gas supplier, call

the fire department.

Installation and service must be performed by
a qualified installer, service agency, or gas
supplier.

AVERTISSEMENT

Assurez-vous de bien suivres les instructions
données dans cette notice pour réduire au
minimum le risque d’incendie ou d’explosion ou
pour éviter tout dommage matériel, toute
blessure ou la mort.

Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre
appareil.

QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareils.
• Ne touchez à aucun interrupteur. Ne pas vous

servir des téléphones dansle bâtiment où vous
vous trouvez.

• Appelez immédiatement votre fournisseur de

gaz depuis un voisin. Suivez les instructions
du fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de

gaz, appelez le sservice des incendies.

L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié ou
par le fournisseur de gaz.

WARNING

FOR YOUR SAFETY:

 This product must be installed and serviced by a professional service

technician, qualified in hot water boiler installation and maintenance. Improper installation and/or
operation could create carbon monoxide gas in flue gases which could cause serious injury, property
damage, or death. Improper installation and/or operation will void the warranty.

Summary of Contents for EBP Series

Page 1: ...les instructions données dans cette notice pour réduire au minimum le risque d incendie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareils Ne touchez ...

Page 2: ...TION 1 Caring For Your Endurance 1A General Care 5 1B Annual Inspection of Flues and Vents 5 1C Shutting Down the Endurance 5 1D To Restart Endurance 5 1E In the Event of Power Failure 5 1F Full Service Every 3 Years 5 1G Trouble Shooting Fault Codes 8 ...

Page 3: ... to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information above on this label 2 Set the thermostat to lowest setting 3 Turn off all electric power to the appliance 4 This appliance is equipped with an ignition device which automatically lights the burner Do not try to light the burner by hand 5 Removecontrola...

Page 4: ...e plancher QUE FAIRE EN CAS D ODEUR DE GAZ N essayez pas d allumer n importe quelque appareil que ce soit Ne touchez pas à un commutateur électrique N utilisez pas le téléphone de votre résidence Appelez immédiatement votre fournisseur de gaz en utilisant le téléphone de votre voisin Suivez les instructions de votre fournisseur de gaz Si vous ne pouvez joindre votre fournisseur de gaz appelez le s...

Page 5: ... 3 5 If after three attempts you still are unable to achieve ignition shut down the boiler and call your service technician If drained follow these steps 1 Follow Installation Manual for proper filling and purging 2 Turn on main manual gas valve 3 Remove control access panel and top front cover and turn on gas shutoff valve above combination gas control valve 4 Switch on main disconnect switch dep...

Page 6: ...LAARS HEATING SYSTEMS Page 6 Figure 1 EBP Assembly View Figure 2 EDP EDN Assembly View Figure 3 Vent Terminal Outside Wall Vent Terminal Gas Shutoff Valve Gas Shutoff Valve ...

Page 7: ...ge Reset Button Return Supply Heating Systems Fittings Main Disconnect Switch Field Wiring Box Relief Valve Gas Supply Manual Main Shutoff Domestic Hot Water Connections Drip Leg Cap Front View Side View Rear View Removable Front Cover Temperature LED Display Removable Control Access Panel Reset Button Heating Systems Fittings Return Pressure Gauge Supply Manual Main Shut Off Drip Leg Cap Relief V...

Page 8: ...er Control Fault Codes F1 Boiler control internal error Switch off boiler and restart If F1 repeats replace boiler control F3 Gas valve status is on with no call for heat This is an indication of a wiring error or a seized relay Check relay first and then boiler wiring F4 Supply sensor error Check for damaged wiring or poor connection first Check sensor resistance per installation manual F5 Tank s...