To restore default memory settings:
Turn OFF power to the puller.
While simultaneously pressing
the Clear and the 7
on the numeric keypad, turn the power ON.
◆
The factory default settings are restored. The M-
Trim control performs the power up routine
described in Powering Up, Section 4.
Set any user-specific memory settings after you have restored
the default memory settings. Using the Puller Control Settings
found on the tables on pages F-1 and F-2 restore your control
to it’s normal operating state:
Open the flap
at the bottom of the M-Trim control.
Press the Control Select button.
Enter the desired two-digit code number
(from the tables on pages F-1 and F-2).
Press the Enter button.
◆
The two-digit code displays in the lower digital dis-
play.
◆
The current parameter value displays in the upper
digital display.
◆
The numeric keypad is enabled.
If necessary, use the numeric keypad to enter a new value.
R
ESTORING
D
EFAULT
M
EMORY
S
ETTINGS
WARNING
This procedure restores the M-Trim control to
the factory default settings. Any user-entered
parameters or programming will be erased.
1
2
1
R
ESTORING
U
SER
-S
PECIFIC
M
EMORY
S
ETTINGS
2
3
4
CAUTION
Press the Enter button within 10 seconds to
accept the new number. Otherwise the para-
meter reverts to the previous value.
UGE048/1103
CSC Combination Puller/Cutter
T
ROUBLESHOOTING
6-15