![Cisco Catalyst 2350 Command Reference Manual Download Page 522](http://html.mh-extra.com/html/cisco/catalyst-2350/catalyst-2350_command-reference-manual_67583522.webp)
A-12
Catalyst 2350 Switch Command Reference
OL-19055-01
Appendix A Catalyst 2350 Switch Boot Loader Commands
fsck
fsck
Use the
fsck
boot loader command to check the file system for consistency.
fsck
[
-test
|
-f
]
filesystem
:
Syntax Description
Defaults
No file system check is performed.
Command Modes
Boot loader
Command History
Usage Guidelines
To stop an in-progress file system consistency check, disconnect the switch power and then reconnect
the power.
Examples
This example shows how to perform an extensive file system check on flash memory:
switch: fsck -test flash:
-test
(Optional) Initialize the file system code and perform extra POST on flash memory.
An extensive, nondestructive memory test is performed on every byte that makes up
the file system.
-f
(Optional) Initialize the file system code and perform a fast file consistency check.
Cyclic redundancy checks (CRCs) in the flashfs sectors are not checked.
filesystem
:
Alias for a flash file system. Use
flash:
for the system board flash device.
Release
Modification
12.2(46)EY
This command was introduced.