2-350
Catalyst 2350 Switch Command Reference
OL-19055-01
Chapter 2 Catalyst 2350 Cisco IOS Commands
show monitor
Examples
This is an example of output for the
show monitor
user EXEC command on a switch:
Switch#
show monitor
Session 1
---------
Type : Local Session
Source Ports :
RX Only : Gi0/1
Both : Gi0/2-3,Gi0/5-6
Destination Ports : Gi0/20
Encapsulation : Replicate
Ingress : Disabled
Session 2
---------
Type : Remote Source Session
Source VLANs :
TX Only : 10
Both : 1-9
Dest RSPAN VLAN : 105
This is an example of output for the
show monitor
user EXEC command for local SPAN source
session 1:
Switch#
show monitor session 1
Session 1
---------
Type : Local Session
Source Ports :
RX Only : Gi0/1
Both : Gi0/2-3,Gi0/5-6
Destination Ports : Gi0/20
Encapsulation : Replicate
Ingress : Disabled
This is an example of output for the
show monitor
session all
user EXEC command when ingress traffic
forwarding is enabled:
Switch#
show monitor session all
Session 1
---------
Type : Local Session
Source Ports :
Both : Gi0/2
Destination Ports : Gi0/3
Encapsulation : Native
Ingress : Enabled, default VLAN = 5
Ingress encap : DOT1Q
Session 2
---------
Type : Local Session
Source Ports :
Both : Gi0/8
Destination Ports : Gi0/12
Encapsulation : Replicate
Ingress : Enabled, default VLAN = 4
Ingress encap : Untagged
Related Commands
Command
Description
monitor session