3 - CONTROLS AND INSTRUMENTS
SCR system technical faults, failures, and engine power loss levels
Visual display
warning
Indicator
light
Indicator
light status
Audible
alarm
Description
DEF/AdBlue
Injection
Failed Torque
Limited”
Active
Active
SCR fault/failure detected.
Up to
25 %
torque reduction within
25 min
of engine
running time. Contact your local authorized dealer for
repair.
DEF/AdBlue
Injection Failed
Power Limited”
Active
Active
SCR fault/failure detected
90 min
after the initial warning
Up to
65 %
torque reduction and
40 %
engine speed
reduction within
40 min
of engine running time. Contact
your local authorized dealer for repair.
DEF/AdBlue
Injection Failed
Power Limited”
Active
Active
SCR fault/failure detected
240 min
after the initial warning.
Engine speed reduced to low idle within
30 min
of engine
running time. Contact your local authorized dealer for
repair.
DEF/AdBlue
Injection Failed
Power Limited”
Active
Active
Emergency re-start is active.
No engine power loss. Engine will be reduced to low
idle after
30 s
of continued operation. Contact your local
authorized dealer for repair.
Resetting the Selective Catalytic Reduction (SCR) system
For DEF/AdBlue® storage tank fluid level faults, failures that can cause engine power loss:
• The DEF/AdBlue® tank level must be raised above
15 %
total volume.
• The key switch must be cycled to the Off position or throttle returned to low idle position.
For DEF/AdBlue® quality and SCR system technical faults, failures that can cause engine power loss:
• To fully reset the system, the component/failure causing the fault must be repaired or replaced.
• Switching off the engine will reset the system and the engine will restart at full power.
• If the same failure is re-detected within
40 h
of engine operation, the last active engine power loss level will be
activated.
• If the same failure is detected three consecutive times within
40 h
of engine operation, maximum engine power loss
will remain active after engine restart until the system is repaired.
• Please contact your authorized CASE CONSTRUCTION dealer for service.
Emergency re-start
NOTE:
Emergency re-starts are only enabled after the engine has been commanded to low idle.
If full power loss is experienced, it may be impossible for the machine to move under its own power. Emergency
re-starts are available to provide the capability to move the machine.
• Allows
30 s
of operation without power loss.
• After
30 s
, the engine is automatically reduced to low idle speed.
• There is no limit to the number of emergency re-starts
3-23
Summary of Contents for 2050M
Page 22: ...1 GENERAL INFORMATION 1 16 ...
Page 106: ...4 OPERATING INSTRUCTIONS 21 Check the controls for correct operation 4 4 ...
Page 136: ...5 TRANSPORT OPERATIONS 5 14 ...
Page 196: ...7 MAINTENANCE RAIL13DOZ1597GA 1 7 40 ...
Page 197: ...7 MAINTENANCE RAIL13DOZ1598GA 2 7 41 ...
Page 198: ...7 MAINTENANCE RAIL13DOZ0003GA 3 7 42 ...
Page 264: ...7 MAINTENANCE RAIL12DOZ1024FA 2 7 108 ...