7 - MAINTENANCE
Hydraulic oil
WARNING
Pressurized hydraulic fluid can penetrate the skin and cause severe injuries.
Hydraulic fluid is under extreme pressure. Rest the bucket or attachment on the ground. Shut the
engine off, turn the key on, and move the hydraulic control lever through all movements several times
to relieve residual pressure in the system.
Failure to comply could result in death or serious injury.
W0161A
Check the level of the hydraulic oil tank every 10 hours or each day.
Prior operation:
Keep all unauthorized personnel clear of the area. Park the machine on level ground, in neutral with the parking
brake applied, and the attachment lowered to the ground. Make sure that all residual pressure is relieved from circuits
before beginning maintenance.
Service specifications
Type of oil
T
UTELA
A
UTO
S
UPREME
™ E
NGINE OIL
SAE 10W-30
Total system capacity
210 L
(
55 US gal
)
Fluid level check
1. Before you start the engine, check the oil level in the
sight gauge. If the oil is cold, the level is correct when
the top of the oil is aligned with the indicator mark on
the sight gauge
(1)
.
2. If oil is required, make certain that all pressure is re-
lieved in the system.
RAIL13DOZ1686AA
1
3. Slowly loosen the tank cap
(2)
and top off until the
proper oil level is reached.
RAPH12DOZ0048AA
2
7-33
Summary of Contents for 2050M
Page 22: ...1 GENERAL INFORMATION 1 16 ...
Page 106: ...4 OPERATING INSTRUCTIONS 21 Check the controls for correct operation 4 4 ...
Page 136: ...5 TRANSPORT OPERATIONS 5 14 ...
Page 196: ...7 MAINTENANCE RAIL13DOZ1597GA 1 7 40 ...
Page 197: ...7 MAINTENANCE RAIL13DOZ1598GA 2 7 41 ...
Page 198: ...7 MAINTENANCE RAIL13DOZ0003GA 3 7 42 ...
Page 264: ...7 MAINTENANCE RAIL12DOZ1024FA 2 7 108 ...