145
Supervisor variable table
k.air +030220981 rel. 1.2 - 01.12.2020
Variable
D
escription
D
im Modbus
BAC
net
Al_LineFault_ZA_RetFan.Active
ZA return fan - Line fault - Alarm status
1
DI1206
BV1432
Al_HallSensor_ZA_RetFan.Active
ZA return fan - Hall sensor - Alarm status
1
DI1207
BV1433
Al_FireAlrm_ZA_RetFan.Active
ZA return fan - Fire alarm - Alarm status
1
DI1208
BV1434
Al_MotorBlock_ZA_RetFan.Active
ZA return fan - Motor block - Alarm status
1
DI1209
BV1435
AuxPrb_4.PrbOk_R
Auxiliary probe 4 - Probe working correctly
1
DI121
BV579
Al_PeakCurrent_ZA_RetFan.Active
ZA return fan - Peak current - Alarm status
1
DI1210
BV1436
Al_ErrCfgB2P.Active
IO - Confi guration error - Alarm status
1
DI1211
BV1437
Al_HighSupplyTemp.Active
High supply temperature - Alarm status
1
DI1212
BV1438
Al_VDI_HygieneInspection_0_0.Active
Alarm VDI - Hygiene Inspection - Alarm status
1
DI1213
BV1439
Al_VDI_OutdoorAirInlets_1_1.Active
Alarm VDI - Check for contamination, damage and corrosion
- Alarm status
1
DI1214
BV1440
Al_VDI_Dehum_3_1.Active
Alarm VDI - Check for contamination, damage and corrosion
- Alarm status
1
DI1215
BV1441
Al_VDI_Dehum_3_2.Active
Alarm VDI - Function check drain and syphon - Alarm status
1
DI1216
BV1442
Al_VDI_Dehum_3_3.Active
Alarm VDI - Clean wet cooler, mist collector and condensate
tray - Alarm status
1
DI1217
BV1443
Al_VDI_AHUHousing_4_1.Active
Alarm VDI - Check for contamination, damage and corrosion
on the air side - Alarm status
1
DI1218
BV1444
Al_VDI_AHUHousing_4_2.Active
Alarm VDI - Check for water precipitation - Alarm status
1
DI1219
BV1445
AuxPrb_4.Alrm_R
Auxiliary probe 4 - Alarm probe broken or disconnected
1
DI122
BV580
Al_VDI_AHUHousing_4_3.Active
Alarm VDI - Check empty housings for contamination, dama-
ge, and corrosion - Alarm status
1
DI1220
BV1446
Al_ VDI_ AirHumWithNoClearW_ 6_ 2_1.Active
Alarm VDI - Check for contamination, damage, microbial
growth and corrosion - Alarm status
1
DI1221
BV1447
Al_ VDI_ AirHumWithNoClearW_ 6_ 2_2.Active
Alarm VDI - Check condensate precipitation in the humidifi er
chamber - Alarm status
1
DI1222
BV1448
Al_ VDI_ AirHumWithNoClearW_ 6_ 2_3.Active
Alarm VDI - Check vapour distribution system for deposit -
Alarm status
1
DI1223
BV1449
Al_ VDI_ AirHumWithNoClearW_ 6_ 2_4.Active
Alarm VDI - Check spray nozzle for deposits - Alarm status
1
DI1224
BV1450
Al_ VDI_ AirHumWithNoClearW_ 6_ 2_5.Active
Alarm VDI - Check drain - Alarm status
1
DI1225
BV1451
Al_ VDI_ AirHumWithNoClearW_ 6_ 2_6.Active
Alarm VDI - Determine number of CFU in the humidifi er water
- Alarm status
1
DI1226
BV1452
Al_ VDI_ AirHumWithNoClearW_ 6_ 2_7.Active
Alarm VDI - Function check control valve - Alarm status
1
DI1227
BV1453
Al_ VDI_ AirHumWithNoClearW_ 6_ 2_8.Active
Alarm VDI - Check humidity limiter - Alarm status
1
DI1228
BV1454
Al_VDI_AirFilt_8_1.Active
Alarm VDI - Check for unacceptable contamination and
damage (leakage) and odours - Alarm status
1
DI1229
BV1455
Ain_SetP.Enable_W
Setpoint by AIN - Enable input
1
DI123
BV581
Al_VDI_AirFilt_8_2.Active
Alarm VDI - Check diff erential pressure - Alarm status
1
DI1230
BV1456
Al_VDI_AirFilt_8_3.Active
Alarm VDI - Maximum interval until fi rst fi lter stage is to be
changed - Alarm status
1
DI1231
BV1457
Al_VDI_AirFilt_8_4.Active
Alarm VDI - Maximum interval until second fi lter stage is to be
changed - Alarm status
1
DI1232
BV1458
Al_VDI_AirDuct_9_1.Active
Alarm VDI - Check accessible duct section for damage - Alarm
status
1
DI1233
BV1459
Al_VDI_AirDuct_9_2.Active
Alarm VDI - Check two or three representative locations on
inner ducts surface for contamination, corrosion, and water
precipitation - Alarm status
1
DI1234
BV1460
Al_VDI_Silencers_11_1.Active
Alarm VDI - Check silencers for contamination. Damage, and
corrosion - Alarm status
1
DI1235
BV1461
Al_VDI_Fan_12_1.Active
Alarm VDI - Check for contamination, damage, and corrosion
- Alarm status
1
DI1236
BV1462
Al_VDI_HeatExch_13_1.Active
Alarm VDI - Visual inspection of air- to- air plate or cross fl ow
heat exchanger for contamination damage and corrosion -
Alarm status
1
DI1237
BV1463
Al_VDI_HeatExch_13_2.Active
Alarm VDI - Visual inspection of air- to- air rotary heat exchan-
ger for contamination damage and corrosion - Alarm status
1
DI1238
BV1464
Al_VDI_HeatExch_13_4.Active
Alarm VDI - Heaters: Check for contamination damage, corro-
sion and tightness - Alarm status
1
DI1239
BV1465
Ain_SetP.Confi gured_R
Setpoint by AIN - Analog input confi gured
1
DI124
BV582
Al_VDI_HeatExch_13_5.Active
Alarm VDI - Coolers: Check tube bundles, mist collectors and
condensate tray for contamination, corrosion, damage and
tightness - Alarm status
1
DI1240
BV1466
Al_VDI_HeatExch_13_6.Active
Alarm VDI - Function-check drain and syphon - Alarm status
1
DI1241
BV1467
Al_VDI_SupplyHum.Active
Alarm VDI - Supply humidity probe is needed - Alarm status
1
DI1242
BV1468
Al_DoorSw.Active
Alarm - Door open - Alarm status
1
DI1243
BV1469
Al_FireSmoke.Active
Alarm - Fire/Smoke - Alarm status
1
DI1244
BV1470
Al_SrsAlrmByDin.Active
Serious alarm from digital input - Alarm status
1
DI1245
BV1471
Al_GenericWarnByDin.Active
Generic warning from digital input - Alarm status
1
DI1246
BV1472
Al_Sup1_DirtyFiltByDin.Active
Supply - Dirty fi lter alarm - Alarm status
1
DI1247
BV1473