11
Introduction
k.air +030220981 rel. 1.2 - 01.12.2020
1.3.4
D
iff erential air pressure switches/fl ow switches
30220980_005_R01
PRESSURE SWITCHES
P
/
N
R
ange
O
utput
DCPD000100
0.5 to 5 mbars
ON/OFF
DCPD001100
0.2 to 2 mbars
ON/OFF
Tab. 1.f
FLOW SWITCHES
P
/
N
R
ange
O
utput
DCFL000100
1-9 m/s
ON/OFF
Tab. 1.g
Fig. 1.h
1.3.5
A
ir quality sensor for rooms and ducts
30220980_006_R01
CO
2
SENSORS
C
od.
R
ange
O
utput
DPWQ402000
0…2000 ppm
0…10 V
DPDQ402000
0…2000 ppm
0…10 V
Tab. 1.h
Fig. 1.i
1.3.6 p
GD
E graphic terminal
30220980_007_R01
The pGDE graphic terminal part number PGNE000* allows complete graphics mana-
gement, with icons and international fonts.
Installation accessories:
• telephone connection cable for k.Air large P/N S90CONN00*;
• connection cable for k.Air mini P/N S90CONN0S0;
• junction card TCONN6J000 (for distances > 10 m, see technical leafl et +050002895).
See technical leafl et +050001425.
Fig. 1.j
1.3.7 th-Tune
terminal
30220980_008_R01
th-Tune part number AT* is the room terminal that, together with the k.Air program-
mable controller, allows the user to set the room temperature and humidity (when
the corresponding probes are available). Based on the model, the power supply can
be chosen between 230 Vac and 24 Vac/Vdc. th- Tune is compatible with the main
recessed wall boxes on the market. The temperature set point can be set simply
and intuitively using the front knob. For assembly details, see the technical leafl et
+0500016IE.
Fig. 1.k
1.3.8 p
GDX
terminal
30220980_010_R01
The 4.3-inch pGDx graphic terminal, P/N PGB04*** is part of the touch screen family,
designed to make the user interface with k.Air controllers simple and intuitive. The
electronic technology used and the 65K colour display enable management of high
quality images and advanced features to ensure a high aesthetic standard. The touch
screen display guarantees simple human- machine interaction, making it easier to
browse between the various screens. The pGDx terminal can be used to fully browse
the k.Air webserver, thus acting as a unit terminal. In the version with built-in T/H pro-
be, it can be used as a room terminal, getting the temperature and humidity values
directly from the main controller.
Fig. 1.l