![Canon imagePROGRAF IPF9000S Troubleshooting Manual Download Page 97](http://html1.mh-extra.com/html/canon/imageprograf-ipf9000s/imageprograf-ipf9000s_troubleshooting-manual_4025287097.webp)
Chapter 4
More Sophisticated Fault Isolation Tasks
3-23
Lift
motor
Carriage HP sensor
Coupling
iPF800/
iPF8000
Series
Coupling
Lift
motor
iPF700
Series
T01
Switch on
Operational
Replace the carriage unit
Does the carriage lift up
and down?
Faulty sensor detection system
Is the carriage in contact
with the edge of the HP?
Ye
s
No
Switch off and move the carriage
by hand; does the carriage hits
the edge of the HP?
Yes
No
Remove foreign matter
Is the carriage in contact
with the coupling?
Main unit not
rotating
C
a
rri
ag
e s
id
e
not
rot
a
ting
Faulty lift motor and bundled
wires, and faulty gear
Replace the main PCB
iPF700/iPF800/iPF8000 Series
Flow 2
Faulty carriage encoder
Summary of Contents for imagePROGRAF IPF9000S
Page 2: ......
Page 3: ......
Page 6: ......
Page 7: ...Chapter 1 Using This Guide...
Page 8: ......
Page 10: ......
Page 11: ...Chapter 2 Trouble Database...
Page 12: ......
Page 72: ......
Page 73: ...Chapter 3 More Sophisticated Fault Isolation Tasks...
Page 74: ......
Page 103: ...Chapter 4 More Sophisticated Fault Isolation Tasks 3 29 Explanatory drawing 7...
Page 118: ......
Page 119: ...Chapter 4 Fault Isolation Tool Collection...
Page 120: ......
Page 153: ...Chapter 5 Miscellaneous Information...
Page 154: ......
Page 175: ...Chapter 6 Main Unit Configuration Diagrams...
Page 176: ......