Chapter 2
Indexes by Case
2-55
Panel display
Code
(last 4
digits)
Large LCD
Small
LCD 1
Small
LCD 2
Explanation/Detection sequence
Remedial Action
(
★
: Reference fault
isolation procedure
or tool)
404A
ERROR
E194-404A
Call for service.
ERROR
E194-404
A
Call For
Service
Non-ejection count error
A non-ejection part operation counter has
reached a specified limit.
Check the parts
counter and
replace the
target unit or
Refresh Service
Kit.
Initialize the parts
counter for the
target unit after
the replacement.
404B
ERROR
E199-404B
Call for service.
ERROR
E199-404
B
Call For
Service
Temperature/humidity
sensor
error
When temperature 0 and humidity 0% are
detected, the detection mechanism is
considered failed and an error message is
displayed.
①
Restart the
printer in
service mode
to clear the
error.
②
Identify the
firmware
version and
update the
firmware to the
last release if
it is earlier
than Ver.1.31
(firmware
defect
)
.
③
Remove and
reinsert the
temperature/h
umidity sensor
PCB
connector
④
Replace the
temperature/h
umidity sensor
PCB.
404C
ERROR
E196-404C
Call for service.
ERROR
E196-404
C
Call For
Service
Serial
number
information mismatch
A mismatch has been detected between the
serial number information stored in the
EEPROM on the main PCB and that stored
in the EEPROM on the MTC relay PCB at
startup.
①
Check to see if
the correct
PCB is
mounted,
since a PCB of
the wrong
model may
have been
mistakenly
mounted
during
servicing.
②
Invoke service
mode to
implement
PCB
replacement.
Summary of Contents for imagePROGRAF IPF9000S
Page 2: ......
Page 3: ......
Page 6: ......
Page 7: ...Chapter 1 Using This Guide...
Page 8: ......
Page 10: ......
Page 11: ...Chapter 2 Trouble Database...
Page 12: ......
Page 72: ......
Page 73: ...Chapter 3 More Sophisticated Fault Isolation Tasks...
Page 74: ......
Page 103: ...Chapter 4 More Sophisticated Fault Isolation Tasks 3 29 Explanatory drawing 7...
Page 118: ......
Page 119: ...Chapter 4 Fault Isolation Tool Collection...
Page 120: ......
Page 153: ...Chapter 5 Miscellaneous Information...
Page 154: ......
Page 175: ...Chapter 6 Main Unit Configuration Diagrams...
Page 176: ......