![Canon imagePROGRAF IPF9000S Troubleshooting Manual Download Page 146](http://html1.mh-extra.com/html/canon/imageprograf-ipf9000s/imageprograf-ipf9000s_troubleshooting-manual_4025287146.webp)
Troubleshooting Guide
4-26
■
Nozzle check print and chip layout (Double-head model example
)
Layout of head contact pins exposed with the head removed
GND
GND
GND
A
B
D
F
GND
GND
GND
F
GND
GND
E
※
D
C
C
B
A
GND
GND
B
A
B
C
D
E
E
F
F
D
E
E
D
D
C
C
A
C
B
A
B
F
E
F
A
Tester
*Inaccessible for checking on the iPF5000 Series.
Left
head
Right
head
A
B
C
D
E
F
A
B
C
D
E
F
Example 3: Main controller and head contact pin continuity check
1. Identify the color (chip) that has been found to have an imaging failure in a Nozzle Check Print operation.
2. Connect flat cable
③
a under test to connector J02 of the flat cable checker.
3. Connect the
―
terminal of the tester to any grounding terminal (GND as shown below).
4. Chips (A through F) have a specific color to control each and also have six contacts each. Check all these contacts for
continuity.
5. With the E-chip, for example, apply the + terminal of the tester to the contact at position E shown below to check for
continuity. (An example of making a continuity check on E-chip signals is shown below.)
Summary of Contents for imagePROGRAF IPF9000S
Page 2: ......
Page 3: ......
Page 6: ......
Page 7: ...Chapter 1 Using This Guide...
Page 8: ......
Page 10: ......
Page 11: ...Chapter 2 Trouble Database...
Page 12: ......
Page 72: ......
Page 73: ...Chapter 3 More Sophisticated Fault Isolation Tasks...
Page 74: ......
Page 103: ...Chapter 4 More Sophisticated Fault Isolation Tasks 3 29 Explanatory drawing 7...
Page 118: ......
Page 119: ...Chapter 4 Fault Isolation Tool Collection...
Page 120: ......
Page 153: ...Chapter 5 Miscellaneous Information...
Page 154: ......
Page 175: ...Chapter 6 Main Unit Configuration Diagrams...
Page 176: ......