![Canon imagePROGRAF IPF9000S Troubleshooting Manual Download Page 17](http://html1.mh-extra.com/html/canon/imageprograf-ipf9000s/imageprograf-ipf9000s_troubleshooting-manual_4025287017.webp)
Chapter 2
Indexes by Case
2-5
Panel display
Code
(last 4
digits)
Large LCD
Small
LCD 1
Small
LCD 2
Explanation/Detection sequence
Remedial Action
(
★
: Reference fault
isolation procedure
or tool)
1032 GARO
W1223
GARO
W1223
(Image
mode
)
Required item missing
A character out of bounds has been
detected where a group or end parameter
character ought to exist, during Image mode
command decoding.
1034 GARO
W1225
GARO
W1225
(Image
mode
)
Other warning
A character other than <ESC> has been
detected right after the image mode analysis
module entered Image mode or when the
decoding of a single command ended.
1035 GARO
W1231
GARO
W1231
(Setup
mode
)
Unknown command
A command character string other than
RESET, SET, OPCMT0 and OPCMT2 has
been detected in a PJL command.
1036 GARO
W1232
GARO
W1232
(Setup
mode
)
Invalid parameter count
Too many or too few parameters have been
detected during Setup mode command
decoding.
1037 GARO
W1233
GARO
W1233
(Setup mode) Required item missing
The exit parameter is missing in the
EnterGAROMode command and the
UniversalExitLanguage command used in
Setup mode.
1038 GARO
W1234
GARO
W1234
(Setup mode)Data out of bounds
A character string that is not defined as an
environmental variable has been detected.
An unknown environmental variable has
been detected.
A character string that is not defined as an
environmental variable value has been
detected.
The value of an unknown environmental
variable has been detected.
1039 GARO
W1235
GARO
W1235
(Setup mode) Other warning
A character string other than the @PJL
prefix has been detected while the analysis
module was idle.
103A GARO
W1226
GARO
W1226
(Image mode) Image processing table error
No image processing table is being
transmitted, a required image processing
table is unavailable, or an image processing
table contains a value out of bounds.
①
Retransmit.
②
Check with a
different
interface
choice.
③
Try by printing
other data.
④
With RIP, print
from the print
driver.
Supplement:
If
this error
occurs, the print
result would
appear blank.
1040 GL2:
W0501
The memory is full.
GL2:
W0501
HP/GL2 error; Insufficient memory capacity
The size of drawing data exceeds the
processing capacity.
①
Reduce the size
of rendering
data.
②
Replace with
HP RTL data for
manipulation
with On The Fly.
1041 GL2:
W0502
The parameter is
out
of range.
GL2:W05
02
HP/GL2 error; invalid parameter
Data having an invalid number of types of
parameters that follow the command has
been detected.
Verify the data
and fix it.
1042
HP/GL2 error; physical coordinate check
from logical coordinates
Invalid coordinates are included.
Verify the data
and fix it.
Summary of Contents for imagePROGRAF IPF9000S
Page 2: ......
Page 3: ......
Page 6: ......
Page 7: ...Chapter 1 Using This Guide...
Page 8: ......
Page 10: ......
Page 11: ...Chapter 2 Trouble Database...
Page 12: ......
Page 72: ......
Page 73: ...Chapter 3 More Sophisticated Fault Isolation Tasks...
Page 74: ......
Page 103: ...Chapter 4 More Sophisticated Fault Isolation Tasks 3 29 Explanatory drawing 7...
Page 118: ......
Page 119: ...Chapter 4 Fault Isolation Tool Collection...
Page 120: ......
Page 153: ...Chapter 5 Miscellaneous Information...
Page 154: ......
Page 175: ...Chapter 6 Main Unit Configuration Diagrams...
Page 176: ......