User Manual – Rev B
FCS Series II
TAC 302 Tests – Revisions B, C, D, E, F
TAC302
Abnormal Voltage Transients. Rev B, C, D, E, F
Condition
Duration (s)
Over
Voltage
A
140Vrms, 180 msec, tf < 1.25 ms, tr < 1.25 ms
54
B
140Vrms, 180 msec, tf < 1.25 ms, tr = 87 ms
then 135Vrms, ramp down, tr = 253
, tr = 6.41
msec
sec
then 130Vrms, ramp down
then 125Vrms, ramp down, tr > 10 sec
then 115Vrms.
135
C
160Vrms, 78 msec, tf < 1.25 ms, tr < 1.25 ms
54
D
160Vrms, 78 msec, tf < 1.25
,
ms, tr
tr = 71 msec
tr = 87 sec
tr > 253 sec.
then 130Vrms, ramp down, tr = 6.41 sec
n, tr > 10 sec
= 31 ms
then 150Vrms, ramp down
then 140Vrms, ramp down,
then 135Vrms, ramp down,
135
then 125Vrms, ramp dow
then 115Vrms.
E
180Vrms, 50 msec, tf < 1.25 ms, tr < 1.25 ms
54
F
180Vrms, 50 msec, tf < 1.25 ms, tr = 11 ms
then 170Vrms, ramp down, tr = 17 msec
then 160Vrms, ramp down, tr = 3
, tr = 71 msec
tr = 87 sec
then 135Vrms, ramp down, tr > 253
, tr = 6.41
1 msec
then 150Vrms, ramp down
then 140Vrms, ramp down,
sec.
sec
then 130Vrms, ramp down
then 125Vrms, ramp down, tr > 10 sec
then 115Vrms.
135
G
180Vrms, 3 x 20 msec, 0.5 apart, tf
1.25 ms
< 1.25 ms, tr <
54
Under
Voltage
H
85Vrms, 180 msec, tf < 1.25 ms, tr < 1.25 ms
54
I
85Vrms, 180 msec, tf < 1.25
then 90Vrms, ramp up, tr =
ms, tr = 87 ms
253 msec
then 95Vrms, ramp up, tr = 6.41 sec
amp up, tr > 10 sec
135
then 100Vrms, r
then 115Vrms.
J
66Vrms, 78 msec, tf < 1.25 ms, tr < 1.25 ms
54
K
6
th
5Vrms, 78 msec, tf < 1.25 ms, tr = 31 ms
en 75Vrms, ramp up, tr = 71 ms
87 ms
253 msec
6.41 sec
then 100Vrms, ramp up, tr > 10 sec
ec
ec
then 85Vrms, ramp up, tr =
then 90Vrms, ramp up, tr =
then 95Vrms, ramp up, tr =
then 115Vrms.
135
L
45Vrms, 50 msec, tf < 1.25 ms, tr < 1.25 ms
54
M
45Vrms, 50 msec, tf < 1.25
then 55Vrms, ramp up, tr =
ms, tr = 11 ms
17 mse
31 msec
71 msec
87 msec
253 msec
then 95Vrms, ramp up, tr = 6.41 sec
then 100Vrms, ramp up, tr > 10 sec
then 115Vrms.
c
then 65Vrms, ramp up, tr =
then 75Vrms, ramp up, tr =
then 85Vrms, ramp up, tr =
then 90Vrms, ramp up, tr =
135
N
45Vrms, 3 x 20 msec, 0.5 apart, tf < 1.25 ms, tr < 1.25 ms
54
Combined
Transient
O
45Vrms, 20 msec, tf < 1.25 ms, tr < 1.25 ms
135
180Vrms, 50 msec, tf < 1.25 ms, tr = 11 ms
then 170Vrms, ramp down, tr = 17 msec
then 160Vrms, ramp down, tr = 31 msec
then 150Vrms, ramp down, tr = 71 msec
then 140Vrms, ramp down, tr = 87 sec
then 135Vrms, ramp down, tr > 253 sec.
then 130Vrms, ramp down, tr = 6.41 sec
then 125Vrms, ramp down, tr > 10 sec
then 115Vrms.
California Instruments
165
Summary of Contents for FCS Series II
Page 4: ...User Manual Rev B FCS Series II California Instruments 4...
Page 27: ...User Manual Rev B FCS Series II California Instruments 27...
Page 89: ...FCS Series II 89 Figure 5 1 FCS System Block Diagram User Manual Rev B California Instruments...
Page 95: ...User Manual Rev B FCS Series II Figure 6 1 Calibration Setup California Instruments 95...