VOLT FREQ MIN
Standard/Group
RTCA
A(CF)
A(NF)
A(WF)
1
100 100 100 100
Voltage
3
101.5 101.5 101.5 101.5
Frequency
380 390 360 360
Standard/Group
Group1
Group2
Group3
1 104
104
104
Voltage
3
105.5 105.5 105.5
Frequency 390
360
360
Table 8-1: Normal Voltage and Frequency minimum
Standard/Group
RTCA
A(CF)
A(NF)
A(WF)
1
122 122 122 122
Voltage
3
120.5 120.5 120.5 120.5
Frequency
420 410 650 800
Standard/Group
Group1
Group2
Group3
1 122
122
122
Voltage
3
120.5 120.5 120.5
Frequency 410
650
800
Table 8-2: Normal Voltage and Frequency Maximum
This test will set the voltage and fr
The test will last for 30
minutes. The test will be repeated, except group1,
VOLT FREQ MAX
This test will set the voltage and frequency to levels defined by Table 1-2. The test will last for 30
minutes. The test will be repea
ltage setting from Table 1-1 and the
frequency from Table 1-2. The unselected phases will remain at 115 volts. The
←
key
(backspace) will terminate the test at any time.
equency to levels defined by Table 8-1.
using the Voltage setting from Table
. The
←
key (backspace) will terminate the test at any time.
ted, except group1, using the Vo
California Instruments
116
Summary of Contents for FCS Series II
Page 4: ...User Manual Rev B FCS Series II California Instruments 4...
Page 27: ...User Manual Rev B FCS Series II California Instruments 27...
Page 89: ...FCS Series II 89 Figure 5 1 FCS System Block Diagram User Manual Rev B California Instruments...
Page 95: ...User Manual Rev B FCS Series II Figure 6 1 Calibration Setup California Instruments 95...