User Manual – Rev B
FCS Series II
SAC 302 Tests – Revision A
SAC302
Abnormal Voltage Transients. Rev A
Condition
Duration (s)
Over Voltage
A
140Vrms, 1450 msec, tf < 1.25 ms, tr < 1.25 ms
54
B
140Vrms, 1025 msec, tf < 1.25 ms, tr = 850 ms
135
C
160Vrms, 520 msec, tf < 1.25 ms, tr < 1.25 ms
54
D
160Vrms, 390 msec, tf < 1.25 ms, tr = 250 ms
135
E
180Vrms, 98 msec, tf < 1.25 ms, tr < 1.25 ms
54
F
s, 75 msec, tf < 1.25 ms, tr = 50 ms
180Vrm
135
G
180Vrms, 3 x 20 msec, 0.5 apart, tf < 1.25 ms, tr < 1.25 ms
54
Under
Voltage
H
85Vrms, 1450 msec, tf < 1.25 ms, tr < 1.25 ms
54
I
85Vrms, 1025 msec, tf < 1.25 ms, tr = 850 ms
135
J
75Vrms, 520 msec, tf < 1.25 ms, tr < 1.25 ms
54
K
75Vrms, 390 msec, tf < 1.25 ms, tr = 250 ms
135
L
45Vrms, 98 msec, tf < 1.25 ms, tr < 1.25 ms
54
M
45Vrms, 75 msec, tf < 1.25 ms, tr = 50 ms
135
N
45Vrms, 3 x 20 msec, 0.5 apart, tf < 1.25 ms, tr < 1.25 ms
54
Combined
Transient
O
45Vrms, 20 msec, tf < 1.25 ms, tr < 1.25 ms
135
180Vrms, 75 msec, tf < 1.25 ms, tr = 50 ms
California Instruments
153