User Manual – Rev B
FCS Series II
2.6.2 -EHV Option - Supplemental Specifications
Specifications for FCS units with -EHV voltage range option installed are same as standard FCS
unit except where noted below.
Frequency
Range:
45 Hz - 1000 Hz
Voltage:
Ranges (L-N):
Low range
0 - 200 Vrms
High range
0 - 400 Vrms
Current
Model
FCS18-1-HV (single phase)
FCS18-3-HV (three phase)
200 V Range.
90 Arms
30 Arms
400 V Range.
45 Arms
15 Arms
Note:
Current derates linearly from 50% of voltage range to 20% of specified current at 10% of
voltage range.
Note:
Current, maximum amps per phase available. For FCS36/2, currents are times two. For
FCS54/3, currents are times three. 35° C ambient max.
Repetitive Peak Current
200 V Range.
250 Apk
84 Apk
400 V Range.
125 Apk
42 Apk