User Manual – Rev B
FCS Series II
TAC 110 Tests – Revisions B, C, D, E, F
TAC110
Normal Frequency Transients, Rev B, C, D, E, F
Condition
Duration (s)
O
ver
Frequency
A
410 Hz, 10 sec, tr = 40 msec, tf = 40 msec
100
B
420 Hz, 5 sec, tr = 80 msec, tf = 80 msec
80
C
425 Hz, 1 sec, tr = 100 msec, tf = 100 msec
60
D
425 Hz, 1 sec, tr = 100 msec, tf = 10 msec
100
420 Hz, 4 sec, tr = 10 msec, tf = 20 msec
410 Hz, 5 sec, tr = 20 msec, tf = 40 msec
Under
Frequency
E
390 Hz, 10 sec, tr = 40 msec, tf = 40 msec
100
F
80
380 Hz, 5 sec, tr = 80 msec, tf = 80 msec
G
c
60
375 Hz, 1 sec, tr = 100 msec, tf = 100 mse
H
100
375 Hz, 1 sec, tr = 100 msec, tf = 10 msec
c
380 Hz, 4 sec, tr = 10 msec, tf = 20 mse
= 20 msec, tf = 40 msec
390 Hz, 5 sec, tr
Combined
I
375 Hz, 1 sec, tr = 100 msec, tf = 100 msec
62
c
425 Hz, 1 sec, tr = 100 msec, tf = 100 mse
TAC 110 Tests – Revisions A
TAC110
Normal Frequency Transients, Rev A
Condition
Duration (s)
Over Frequency
A
430 Hz, 0.5 cycle, tr = 120 msec, tf = 120 msec
100
B
430 Hz, 0.5 cycle, tr = 300 msec, tf = 1.2 sec
80
C
450 Hz, 0.5 cycle, tr = 200 msec, tf = 200 msec
60
D
450 Hz, 0.5 cycle, tr = 250 msec, tf = 3 sec
100
r Frequency
Unde
E
120 msec
100
370 Hz, 0.5 cycle, tr = 120 msec, tf =
F
e, tr = 300 msec, tf = 1.2 sec/
80
370 Hz, 0.5 cycl
G
c
350 Hz, 0.5 cycle, tr = 200 msec, tf = 200 mse
60
H
350 Hz, 0.5 cycle, tr = 250 msec, tf = 3 sec
100
Combined
I
350 Hz, 0.5 cycle, tr = 200 msec, tf = 200 msec
62
450 Hz, 0.5 cycle, tr = 200 msec, tf = 200 msec
California Instruments
162
Summary of Contents for FCS Series II
Page 4: ...User Manual Rev B FCS Series II California Instruments 4...
Page 27: ...User Manual Rev B FCS Series II California Instruments 27...
Page 89: ...FCS Series II 89 Figure 5 1 FCS System Block Diagram User Manual Rev B California Instruments...
Page 95: ...User Manual Rev B FCS Series II Figure 6 1 Calibration Setup California Instruments 95...