User Manual – Rev B
FCS Series II
TAC 201 Tests – All Revisions
TAC201
Power Interrupt, Rev A, B, C, D, E, F
Condition
Duration (s)
A
Vnom 115V, 50 msec
62
B
Vlow 108V, 50 msec
62
C
Vhigh 118V, 50 msec
62
D
Vnom 115V, 30 msec
62
E
Vlow 108V, 30 msec
62
F
Vhigh 118V, 30 msec
62
G
Vnom 115V, 10 msec
62
H
Vlow 108V, 10 msec
62
I
Vhigh 118V, 10 msec
62
J
Vnom 115V, 3 x 50 msec, 0.5 sec apart
62
K
Vnom 115V, 50 msec
62
160Vrms, 30 msec, tr = 40 msec
L
Vnom 115V, 50 msec
62
70Vrms, 30 msec, tr = 40 msec
California Instruments