Prior to Use

Please read this instruction manual carefully.

Please use product only as directed or severe damage to the product may occur.

Not properly following these guidelines may result in extremely hazardous conditions that could cause electrical shock or fire.

 WARNING

Do not modify the product nor remove the protective enclosure. Under the protective enclosure are 

contained high voltage and high temperature components during normal operation and after complete shutdown.

Avoid electric shock or burns by avoiding them.

Under the protective enclosure are contained high voltage and high temperature components during normal operation and 

after complete shutdown. Avoid electric shock or burns by avoiding them. 

Keep face and hands away at all times during operation to avoid unexpected injury.

DANGER. Risk of fire, electric shock, and injury. DO NOT continually operate if there is smoke, odor, or irregular noise. Instead 

immediately turn off the power and contact us. Do not attempt to repair it yourself because it is dangerous to do so.

DANGER. Risk of fire, electric shock, and injury. DO NOT insert or drop any object in openings, this could cause unit failure or 

severe hazardous conditions.

DANGER. Risk of fire, electric shock, and injury. DO NOT use the product with condensation present, this could result in electric 

shock or fire.

 CAUTION

This power supply is intended to be used as a component of a larger system of electrical equipment.

User is responsible for the safe design when this product is to be integrated in the equipment which requires 

particularly high quality and reliability. There is a possibility to endanger persons or property by a failure or

malfunction of this product.

Avoid sharp and sudden impacts to this unit such as dropping or damage will likely result.

Ensure and maintain input voltage, output current, output power, ambient temperature, and humidity within specification or unit 

may be damaged.

Safety standards for this product are based on the condition that the product is to be used with forced air cooling. To prevent 

the temperature of internal parts from exceeding the specification, ensure that the product is exposed to proper airflow when 

installing

Ensure that wires are properly secured to the input and output terminals as specified in this manual. 

Be sure to turn off the power before making the output connection.   

DO NOT use in a special environment (e.g. in the presence of strong electromagnetic field or erosive gas)  

or environment where conductive foreign substance is present.

DO NOT use or store product where condensation may occur due to moisture or humidity. For use in such conditions, 

waterproof protection is necessary and must be installed.

Do not operate under over current or short-circuit conditions for more than 10 seconds otherwise damage

and electrical insulation failure will likely result.

No stress (e.g. twist, deflection) should be applied to the print board when the product is installed.

Avoid impacts, such as dropping this product.

Do not apply the load to signal connector CN501.

DANGER. Output of this product is regarded as hazardous energy so this should not be accessible to end users.

Use appropriate connecters for the terminal connection.

For the crimping of the contact, use the crimping tool recommended by the manufacturer.

Prevent accidental contact with the output terminal of this product from dropped items such as tools by insuring proper 

orientation and shielding/cover.

Turn off the input power and ensure that the input and output terminal voltage drops to zero.

This product uses fuses in the double pole/neutral line. When it is used for information processing equipment

 (IEC/EN/UL60950-1), the following label must be provided for service engineers.

CAUTION DOUBLE POLE / NEUTRAL FUSING 

Special Instructions for IEC/EN/UL60601-1

CAUTION

These products are not suitable for use in the presence of flammable anesthetic mixtures with oxygen or with nitrous oxide.

These products have not been assessed to IEC/EN/UL60601-1-2(EMC), but EMC test data is available from us.

PFS300A

Series

Instruction Manual

UL60950-1, #E237238 
UL60601-1, #E320635 

RoHS Compliant 

10001-005WE-00

Summary of Contents for PFS300A-12

Page 1: ... on the condition that the product is to be used with forced air cooling To prevent the temperature of internal parts from exceeding the specification ensure that the product is exposed to proper airflow when installing Ensure that wires are properly secured to the input and output terminals as specified in this manual Be sure to turn off the power before making the output connection DO NOT use in...

Page 2: ...501 L AC Line S Output Remote Sensing N AC Neutral VS Output Voltage Check Frame Ground S Output Remote Sensing V Output terminal VS Output Voltage Check V Output terminal Not in use V Output terminal Not in use V Output terminal R Remote Control ON OFF R Remote Control ON OFF CN502 not included Connector S8B PHDSS JST Housing PHDR 08VS Terminal SPHD 001T P0 5 Crimping tool AP K2N For proper conne...

Page 3: ... Inrush Current before powering up again Confirm the forced air convection allows for cooling airflow This unit comes with an integral inrush current limiting Remote Sensing circuit using a power thermistor Since SCR is used to prevent inrush current the inrush current limiting circuit may have been released if the The remote sensing function is built in power is turned on again in a short time Be...

Page 4: ...power supply if it too is configurable in Series in order to increase DC voltage or to provide both and DC voltage In these configurations the MAXIMUM current delivered to the Load is limited to the maximum allowable from the power supply with the lowest current rating To increase VDC PS1 PS2 see configuration 1 below Example If PS1 and PS2 are both 12VDC 30W each then configuration 1 will provide...

Page 5: ...n below For Medical 60601 Mounting direction a b c d PFS300A 12 By derating the output power loading rate this product can be used in a wide temperature range PFS300A 15 24 30 48 15V 24V 30V 48V 強制空冷 2m s時 参考 3 2 3 1 Mounting Method PFS300A 2 0m s 0 20 40 60 80 100 10 0 10 20 30 40 50 60 L o a d Ambient Temperature 0 20 40 60 80 100 10 0 10 20 30 40 50 60 L o a d Ambient Temperature 0 20 40 60 80 ...

Page 6: ... Refer to the following drawing to specify each component location Image from the top view Mounting method Forced air cooling method requires air flow from external fans The insertion length of the power supply mounting screw should be 6mm or less Recommended tightening torque for M4 power supply mounting screws 1 4Nm 3 3 L101 Component name X Capacitor Common mode choke 85 115 115 115 Max Temp de...

Page 7: ...e within spec of 100 240VAC 50 60Hz Confirm all input and output connections are in accordance with above Check the output adjustment potentiometer Sometimes output OVP function turns off the output power when the potentiometer is adjusted too high Please note that an excessive capacitive load can create over current situation Confirm remote on off is getting the appropriate voltage for desired op...