User Manual – Rev B
FCS Series II
2.1.3 AC Measurements
Measurement specifications apply to single chassis FCS Series II AC source in three-phase
mode. See notes for other models and configurations.
Parameter
Range
Accuracy (
±
)
Resolution
1 Phase Mode
3 Phase Mode
Frequency
45.00-1200.0 Hz
0.1% ± 1 digit
0.01 Hz to 81.91 Hz
0.1 Hz to 819.1 Hz
1 Hz > 819.1 Hz
Phase
45.00 - 100.0 Hz
100.0 - 1200 Hz
0.5°
2°
0. 1°
RMS Voltage
0 - 400 Volts
0.05% + 0.25V
0.01 Volt
RMS Current
0 - 150 Amps
0.1% + 0.45A
0.1% + 0.15A
0.001 Amp
Peak Current
0 - 250 Amps
0.2% + 1.5A
0.1% + 0.45A
0.001 Amp
Crest Factor
1.00 – 10.00
1.5 %
1.5 %
0.01
VA Power
0 - 6 KVA
0.3% + 15 VA
0.15% + 5 VA
1 VA
Real Power
0 - 6 KW
0.3% + 15 W
0.15% + 5 W
1 W
Power Factor
0.00 - 1.00
0.03
0.01
0.01
Note: Accuracy specifications are valid above 100 counts. For multi-chassis configurations, Current
and Power range and accuracy specifications are times the number of chassis.
Note: Frequency measurement specification valid for output > 20 Vrms.
Note: Crest Factor accuracy applies for Irms > 50% of max.
Note: Power Factor accuracy applies for PF > 0.5 and VA > 50% of max.
2.1.4 Harmonic Measurements
Harmonic measurement specifications apply to FCS18-3 with –ADV option in three-phase
mode. See notes for single-phase mode or FCS18–1 with –ADV option.
Parameter
Range
Accuracy (
±
)
Resolution
Frequency fundamental
45.00 - 81.91 Hz
82.0 - 819.1 Hz
> 819.1 Hz
0.1% ± 1 digit
0.01 Hz
0.1 Hz
1 Hz
Frequency harmonics
45.00 Hz – 16 kHz
0.1% + 2 digits
0.1 Hz
Voltage
Fundamental 0 - 400 Volts
0.05% + 0.25V
0.01V
Harmonic 2 - 50
0.1% + 0.1%/kHz + 0.25
0.01V
Current
Fundamental 0 - 20 Amps
0.1% + 0.15A
0.01A
Harmonic 2 - 50
0.1% + 0.1%/kHz + 0.05A
0.01A
Note: Current range and accuracy specifications are times three in single-phase mode. For multi-
chassis configurations, current accuracy specifications are times the number of chassis. The harmonic
measurement bandwith increases to 48Khz in single-phase mode.
1
Frequency measurement specifications valid with output voltage of 30Vrms or higher. If output relay is open,
frequency measurement will return 0.0 Hz.
California Instruments
16
Summary of Contents for FCS Series II
Page 4: ...User Manual Rev B FCS Series II California Instruments 4...
Page 27: ...User Manual Rev B FCS Series II California Instruments 27...
Page 89: ...FCS Series II 89 Figure 5 1 FCS System Block Diagram User Manual Rev B California Instruments...
Page 95: ...User Manual Rev B FCS Series II Figure 6 1 Calibration Setup California Instruments 95...