User Manual – Rev B
FCS Series II
SVF 103 Tests
Voltage Phase Difference tests do not apply for single-phase EUT’s.
SVF 104 Tests - Revision F
SVF104
Voltage Modulation Rev F
Condition
Duration (s)
Run at 400, Repeat at 360, 600 and 800 Hz
A
Vmod F = 1.0 Hz, V = 0.375 Vrms
1800
B
Vmod F = 1.7 Hz, V = 0.375 Vrms
1800
C
Vmod F = 10 Hz, V = 2.5 Vrms
1800
D
Vmod F = 25 Hz, V = 2.5 Vrms
1800
E
Vmod F = 70 Hz, V = 0.375 Vrms
1800
F
Vmod F = 100 Hz, V = 0.375 Vrms
1800
G
Vmod F = 200 Hz, V = 0.375 Vrms
1800
SVF 10
R
5 Tests – evision F
SVF105
Frequency Modulation Rev F
Condition
Duration (s)
Run at 400, Repeat at 362, 600 and 798 Hz
A
Fmod F = 1 Hz/sec, Fmod Amp = 4 Hz± 2 Hz
1800
B
Fmod F = 5 Hz/sec, Fmod Amp = 4 Hz± 2 Hz
1800
C
Hz
1800
Fmod F = 10 Hz/sec, Fmod Amp = 4 Hz± 2
D
2 Hz
1800
Fmod F = 25 Hz/sec, Fmod Amp = 4 Hz±
E
z± 2 Hz
1800
Fmod F = 100 Hz/sec, Fmod Amp = 4 H