User Manual – Rev B
FCS Series II
TAC 401 Tests – Revision E, F
TAC401
Emergency SS Limits Volt and Freq. Rev E, F
Condition
Duration (s)
Nominal
Voltage
A
Vnom 115V, Flow 393 Hz
1800
B
Vnom 115V, Fhigh 407 Hz
1800
Low
Voltage
C
Vlow 108V, Fnom 400 Hz
1800
D
Vlow 108V, Flow 393 Hz
1800
E
Vlow 108V, Fhigh 407 Hz
1800
High
Voltage
F
Vhigh 118V, Fnom 400 Hz
1800
G
Vhigh 118V, Flow 393 Hz
1800
H
Vhigh 118V, Fhigh 407 Hz
1800
D
TAC 401 Tests – Revision B,
TAC401
Emergency SS Limits Volt and Freq. Rev B, D
Condition
Duration (s)
Nominal Voltage
A
Vnom 115V, Flow 360 Hz
1800
B
Vnom 115V, Fhigh 440 Hz
1800
Low Voltage
C
Vlow 102V, Fnom 400 Hz
1800
D
Vlow 102V, Flow 360 Hz
1800
E
Vlow 102V, Fhigh 440 Hz
1800
High Voltage
F
Vhigh 124V, Fnom 400 Hz
1800
G
Vhigh 124V, Flow 360 Hz
1800
H
Vhigh 124V, Fhigh 440 Hz
1800
TAC 401 Tests – Revision A, C
TAC401
Emergency SS Limits Volt and Freq. Rev A, C
Condition
Duration (s)
Nominal Voltage
A
Vnom 115V, Flow 360 Hz
1800
B
Vnom 115V, Fhigh 440 Hz
1800
Low Voltage
C
Vlow 104V, Fnom 400 Hz
1800
D
Vlow 104V, Flow 360 Hz
1800
E
Vlow 104V, Fhigh 440 Hz
1800
High Voltage
F
Vhigh 122V, Fnom 400 Hz
1800
G
Vhigh 122V, Flow 360 Hz
1800
H
Vhigh 122V, Fhigh 440 Hz
1800
California Instruments
168
Summary of Contents for FCS Series II
Page 4: ...User Manual Rev B FCS Series II California Instruments 4...
Page 27: ...User Manual Rev B FCS Series II California Instruments 27...
Page 89: ...FCS Series II 89 Figure 5 1 FCS System Block Diagram User Manual Rev B California Instruments...
Page 95: ...User Manual Rev B FCS Series II Figure 6 1 Calibration Setup California Instruments 95...