Brooks Automation
82
278580 Revision A
7 Operation
LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol
Product Manual
"ECID_41"
→
parameter 41 -
Î
Delay time between read cycles
"ECID_42"
→
parameter 42 -
Î
CarrierIDOffset
"ECID_43"
→
parameter 43 -
Î
CarrierIDLength
"ECID_44"
→
parameter 44 -
Î
FixedMID
"ECID_45"
→
parameter 45 -
Î
MIDFormat
"ECID_99"
→
parameter 99 -
Î
Customer code
Head attribute definitions: *
"HeadStatus"
The current status
"HeadID"
Head number 00-31 (2 digits)
* With regard to an RFID Reader LF80C ZeniD, the head attribute definition
"HeadStatus" is equal to the "OperationalStatus" of the CIDRW. The
"HeadID" is also 01 and equal to the CIDRW "Configuration" attribute.
Where used
S18F1, S18F3
Description: Value of the specified attribute.
CIDRW attribute definitions:
"Configuration”
Number of heads "01"
"AlarmStatus”
Current CIDRW sub-status of ALARM
STATUS
"0" …NO
"1" …ALARMS
"OperationalStatus"
Current CIDRW sub-status of OPERATING
"IDLE”
…
Reader in IDLE mode
"BUSY”
…
Reader is busy
"MANT" …
Maintenance mode
"SoftwareRevisionLevel"
Revision (version) of Software - 8-byte
maximum
ECID_00 to ECID_45 see data item ECV parameters 0 - 45
ATTRVAL
Format:
A[max4]