Brooks Automation
90
278580 Revision A
7 Operation
LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol
Product Manual
Description: Result information on the status of the request concerning the
service request.
"NO"
Normal operation
Indicates the success of the requested action.
"EE"
Execute error
Cannot read tag data. Cannot read ID sequence.
However, equipment is normal.
"CE"
Communication error
Syntax error of message or message format or value.
"HE"
Hardware error
ID reader/writer head fault, ID reader/writer head is powered off.
"TE"
Tag error
Where used
S18F2, S18F4, S18F6, S18F8, S18F10, S18F12, S18F14
Description: Indicates an action to be performed by the subsystem.
Used to differentiate between the different subsystem commands indicated.
"ChangeStatus"
…
Change status
"GetStatus"
…
Get status
"Reset"
… Reset
CIDRW
"PerformDiagnostics"… Perform diagnostics
"DefaultParams"
…
Reset default parameter*
"FactorySettingParams" … Reset factory settings and default parameter
“ADJUST“
…
Automatic antenna calibration (parameter 33)
"SetLED“
… Set
LED*
Where used
S18F13
SSACK
Format: A[2]
SSCMD
Format: A[max
18]