Brooks Automation
132
278580 Revision A
7 Operation
LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol
Product Manual
Host writes new reader attributes with S18F3
Host to Reader: S18F3
17:11:07 Outgoing: ENQ ( 05 )
17:11:07 Incoming: EOT ( 04 )
17:11:07 Outgoing: Length Byte ( 77 )
17:11:07 Outgoing: Header ( 01 FF 92 03 80 01 00 00 00 04 )
17:11:07 Outgoing: Data
01 02
41 04 31 32 33 34
01 04
01 02
→
Configuration "01"
41 0D 43 6F 6E 66 69 67 75 72 61 74 69 6F 6E
41 02 30 31
01 02
→
Alarmstatus "0"
41 0B 41 6C 61 72 6D 53 74 61 74 75 73
41 01 31
01 02
→
OperationalStatus "IDLE"
41 11 4F 70 65 72 61 74 69 6F 6E 61 6C 53 74 61 74 75 73
41 04 4D 41 4E 54
01 02
→
SoftwareRevisionLevel "V1.0.0"
41 15 53 6F 66 74 77 61 72 65 52 65 76 69 73 69 6F 6E 4C 65
76 65 6C
41 06 56 31 2E 30 2E 30
17:11:07 Outgoing: Checksum ( F2 02 )
17:11:07 Incoming: ACK ( 06 )
Reader to Host: S18F4
17:11:07 Incoming: ENQ ( 05 )
17:11:07 Outgoing: EOT ( 04 )
17:11:07 Incoming: Length Byte ( 2D )
17:11:07 Incoming: Header ( 81 FF 12 04 80 01 00 00 00 04 )
17:11:07 Incoming: Data
01 03
41 04 31 32 33 34
→
TARGETID "1234"
41 02 4E 4F
→
SSACK "NO"
01 01
01 04
→
STATUS <L4>
41 02 4E 45
→
PMInformation "NE"
41 01 31
→
Alarmstatus "1"
41 04 4D 41 4E 54
→
OperationalStatus "MANT"
41 04 4E 4F 4F 50
→
HeadStatus "NOOP"
17:11:07 Incoming: Checksum ( 08 54 )
17:11:07 Outgoing: ACK ( 06 )
The host writes all fundamental CIDRW attributes defined in ATTRID.
The reader answers with the actual attribute values.